Cleaning; Maintenance; Spare Parts; Transport - Clatronic HDR 3597 Manual De Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 25
Change accessories
1. Switch off the device at the main switch (5).
2. Relieve the existing pressure by activating the lever on the spray
gun.
3. Lock the spray gun.
4. Switch to the required accessory and restart operation.
End operation
1. Switch off the device at the main switch.
2. Disconnect the mains plug from the socket.
3. Close the water supply.
4. Relieve the existing pressure by activating the lever on the spray
gun.
5. Lock the spray gun.
6. Disconnect the device from the water supply by unscrewing the
hose on the water connection of the device.

Cleaning

WARNING:
Always disconnect the mains plug before cleaning.
Do not spray the high-pressure cleaner with the high-pressure jet.
Do not immerse the device in water, not even partially. This may
lead to electric shock or fire.
CAUTION:
Do not use any wire brush or other abrasive objects.
Do not use any acidic or abrasive detergents.
Housing, hose, and mains cable
These parts can be wiped with a soft dry cloth.
For stubborn dirt, gently moisten the cloth.
Then wipe everything dry.

Maintenance

After use, disconnect the hoses from the high-pressure cleaner.
Allow the water to flow out of the high-pressure cleaner and hoses.
After every tenth use, grease the screw and plug-in connections
with vaseline.
After every 5th use, check the filter on the water inlet.
Before use, always check the seals, the power cable, and the
high-pressure hose for damage.
Damaged parts must be replaced by equivalent spare parts.
NOTE:
Inside the high-pressure cleaner, there are no parts that must be
maintained by the user.
If the high-pressure cleaner needs to be repaired, contact your
dealer.

Spare Parts

To order spare parts, please contact your dealer.
Spare part numbers can be found in the "Supplied Parts" table.

Transport

Secure the accessories in the accessories holder.
The high-pressure cleaner can be carried vertically by the handle.
The weight is 5.7 kg.

Storage

Separate the accessories.
Drain the accessories and the high-pressure hose.
CAUTION:
There is always water in the pump of the high-pressure cleaner. Frost
can destroy the pump or internal pipes. Therefore, always keep the
device in a frost-free place.

Troubleshooting

Fault
Possible cause
Device does not
No power supply
work.
Device not switched
on
The motor stops
The overheat protec-
suddenly during
tion of the pump was
operation.
triggered.
No cleaning agent
Cleaning agent tank
drawn.
blocked.
The device does
Fault lies in the
not reach operat-
water feed.
ing pressure.
The high-pressure
nozzle is blocked.
Fault lies in the
high-pressure cleaner.
Major fluctuations
The pump is drawing
in pressure
air.
The high-pressure
nozzle is blocked.
Seals or valves in
the high-pressure
cleaner are dam-
aged.
Pump is leaking
Stop operation
immediately.
Solution
Check the mains connection
and the fuse. Replace the
extension cables if necessary.
Check the position of the main
switch.
Switch the device off and
disconnect the plug. Allow the
device to cool for approx.
30 min.
Then restart.
Check the nozzle and hoses
in the cleaning agent tank.
Dilute the cleaning agent
before pouring it in.
Clean the filter in the water
connection.
Check whether enough water
comes out of the tap.
If necessary, check the back-
flow preventer.
Check whether the water
hose to the pump is leaking or
is kinked.
Clean the high-pressure
nozzle. See "Cleaning the
high-pressure nozzle" in this
chapter.
Please contact your dealer.
Check the hose connections
and whether the water hose is
sealed.
Clean the high-pressure
nozzle. See "Cleaning the
high-pressure nozzle" in this
chapter.
Please contact your dealer.
Please contact your dealer.
41

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido