COD. 1224076 / 2.1
KEYPAD-DCS / KEYPAD-M-DCS
Wireless keypad compatible with the receivers and units from the DCS range.
CHARACTERISTICS
- Allows to program 4 different codes which will operate 4 different channels.
- Codification from 1 to 8 numbers.
- The codes will not be lost from the memory although you disconnect the battery.
- In stand-by mode the power consumption of the keypad is reduced in order to enlarge battery's life.
- To activate the keypad and enter a code, it is necessary to wake up the keypad by pressing any key.
- We recommend to change the pre-programmed codes.
Channel 1
1111
TECHNICAL CHARACTERISTICS
Operating frequency
Power supply
Consumption
Radiated power
Operating temperature
Estanqueidad
Size
Range
NEW ACCESS CODE PROGRAMMING
Verify that jumper J1 is positioned in operating mode.
Press P key. The LED will flash
Enter master code (see label "Mastercode" in the German manual)
Press the BELL key. The Led will flash quicker.
Enter the new code, from 1 to 8 digits.
Enter the channel to operate (it has to be a number from 1 to 4 related to the channels of the receiver, after
entering the new code)
Press the BELL key. The LED will turn off and the new code will be programmed with the selected channel.
To save it into receiver, open receiver programming mode, press the access code and the BELL key from the
keypad, the
receiver will make a confirmation beep, wait a few seconds to allow receiver to close programming mode.
OPERATING
Press memorized code and BELL key.
After 20 seconds, the keypad will stop transmitting.
To reduce the transmitting time, press again the BELL key.
LOW BATTERY
If the LED turns on for 5 seconds, it indicates low battery.
HOW TO CHANGE MASTER CODE:
If you want to change the master code:
Press P key. The LED will flash
Enter the actual master code (see label "mastercode" in German manual)
Press BELL key. The LED will flash quicker.
Press P key. The LED will increase the flash frequency.
Enter new master code, 8 digits maximum.
Press BELL key. The LED will turn off and the new code is programmed.
USE OF THE EQUIPMENT
Designed for control access applications. Not guaranteed for other uses.
The manufacturer reserves the right to alter equipment specifications without prior notification.
DECLARATION OF CE CONFORMITY
See web www.jcm-tech.com
Channel 2
2222
Channel 3
433,92MHz
Pila 9V
10mA
<10mW
-20ºC a +55ºC
IP54 minimum
82x82x30mm
30m
3333
Channel 4
4444
GB