Good sensitivity
INSTALLATION: (see the diagram)
➢
Shut off power.
➢
Loosen the screw on the bottom lid, open
the wiring hole, pass the wire of power and
load through the bottom lid.
➢
Fix the bottom lid with inflated screw on the
selected position.
➢
Connect the power and load wire into
connection-wire column according to the connecting figure.
➢
Put the sensor on the bottom lid, twist the screw tightly then electrify it and test it.
CONNECT-WIRE FIGURE
(See the right figure)
TEST:
➢
Turn time knob anti-clockwise to the minimum; turn the
LUX knob clockwise to the maximum (SUN), Switch on
power, the controlled load should not work, needing to
preheat within 5-30sec.
➢
The sensor will be sensed again in 5-10sec later when
the first induction is finished, the load should work when
received sensor signal and stop working within 7-13sec
with no any sensor signal.
➢
Turn LUX knob to minimum anti-clockwise, if you test it when the ambient light is more than
10LUX, the induction load would not work after the load stops working; the load should work
if you cover the detection window with opaque object (towel etc),it would be regular the load
stops to work within 7-13sec under no induction signal condition.
Note: when testing in daylight, please turn LUX knob to
position, otherwise the sensor lamp could not work!
NOTE:
➢
➢
Poor sensitivity
➢
➢
➢
➢
SOME PROBLEM AND SOLVED WAY:
➢
➢
➢
Should be installed by electrician or experienced person.
Avoid installing it on the unrest object.
There should be no hindrance and moving objects in front of the detection windows to effect
detection.
Avoid installing it near air temperature alteration zones such as air condition, central heating,
etc.
Considering your safety, please do not open the cover when you find the hitch after
installation.
If there is difference between instruction and the function the product has, please give
priority to product and sorry not to inform you additionally.
The load do not work:
a. please check if the connection-wiring of power and load is correct.
b. please check if the load is good .
c. please check if the working light set correspond to ambient light.
The sensitivity is poor:
a. Please check if there has hinder in front of the detection window to effect to receive
the signal.
b. Please check if the ambient temperature is too high.
c. Please check if the induction signal source is in the detection fields.
d. Please check if the installation height corresponds to the height showed in the
instruction.
e. Please check if the moving orientation is correct.
The sensor can not shut off the load automatically:
a. Please check if there is continual signal in the detection field.
b. Please check if the time delay is the longest.
c. Please check if the power correspond to the instruction.
d. Please check if the temperature near the sensor change obviously, such as air
condition or central heating etc.