Operation; Safety Notes - marklin 60174 Manual Del Usario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 19
LED off
LED on bright
LED on dim
4

Operation

After the Booster has been turned on, it takes a few seconds before the red LED comes
on. The Booster is then ready for operation. While the Booster is in operation, the LED
lights up with different levels of brightness, depending on the situation, and confirms the
correct function.
The 60174 Booster reports different data to the Central Station such as the current con-
sumption and the temperature. The Central Station can display these values at "Setup
Information".
5

Safety Notes

The Booster is designed only for operation in dry areas.
The Booster should be operation only when it is securely mounted on a base or
platform. It should be mounted if possible in a well ventilated location and no
units putting off heat should be mounted near it.
Never operate the Booster on a base or platform this wet or easily set on fire.
The power cord plugs for several switched mode power packs / transformers
should always be connected to a common power strip. The power strip must
always be unplugged from the household current before plugging or unplugging
switched mode power packs / transformers at the power strip!
Power consumption areas must be separated from each other, i.e. the track areas
for the Central Station and for one or more Boosters must be separately elec-
trically from each other. Also, the track areas for two or more Boosters may not
have any electrical contact with each other (Isolate the center conductor only!).
Pay attention to the colors of the wires when connecting the Booster. As with
the Central Station, the red wire must be connected to the center conductor.
Please note that the Booster can become rather warm during operation. It
should therefore be mounted in a location where there is good ventilation and
where there are no other sources of heat such as transformers nearby.
The Booster is not receiving current from the switched mode
power pack / transformer.
The Booster has / was switched to STOP.
The Booster is getting no signal from the Central Station.
The Booster is receiving current from the switched mode power
pack / transformer. The track is being powered correctly.
A locomotive decoder is being read via the Booster.
The Booster is working correctly. The brightness of the LED
decreases as the load on the Booster increases.
9