OPERATION
• Press the push-button control to open the valve.
• Automatic timed shut-off after ~3 seconds or 7 seconds.
REMEMBER
• Our valves must be installed by professional installers in accordance with current regulations
and recommendations in your country, and the specifications of the fluid engineer.
• Sizing the pipes correctly will avoid problems of flow rate, pressure loss and water hammer
(see calculation table in our brochure and online at www.delabie.com).
• Protect the installation with filters, water hammer absorbers and pressure reducers to reduce
the frequency of maintenance (recommended pressure from 1 to 5 bar maximum).
• Install stopcocks close to the valve to facilitate maintenance.
• The pipework, filters, non-return valves, stopcocks, bib taps, cartridge and all sanitary fittings
should be checked at least once a year, and more frequently if necessary.
MAINTENANCE
To shut-off the water supply: close the stopcock by turning the wall-mounted escutcheon.
Alternatively, slide the wall-mounted escutcheon towards you in order to control the stopcock
with a 32mm spanner. To remove the mechanism: remove the push-button with a 2.5mm Allen key
and unscrew the cartridge with a 28mm spanner.
Foreign bodies in the pipework may cause the valve to malfunction.
‑ Timed shut‑off delay is too long or there is continuous flushing:
Clean the inside of the timing delay case with a clean, dry cloth and the timing groove
with a non-metallic point.
‑ Drips or a trickle of water beneath the push‑button:
Replace the cartridge.
Beware: do not grease the inside of the mechanism.
MAINTENANCE & CLEANING
• Cleaning chrome and stainless steel: do not use abrasive, chlorine or any other acid-based
cleaning products. Clean with mild soapy water using a cloth or a sponge.
• Frost protection: drain the pipes and operate the valve several times to drain any remaining water.
In the event of prolonged exposure to frost, we recommend taking the mechanisms apart and storing
them indoors.
For the UK market only: Tel. 01491 821 821 - email: technical@delabie.co.uk
For all other markets: Tel. +33 (0)3 22 60 22 74 - email: sav@delabie.fr
After Sales Care Support:
The installation guide is available on: www.delabie.co.uk
The installation guide is available on: www.delabie.com
EN
10

Publicidad

Tabla de contenido