OPERATING INSTRUCTIONS
0.- Plug in the machine (switch must be in "OFF" position).
1.- Switch on the machine (select "FOR" position).
Positions in (F): OFF – Stop
Use the soft shaft of 40 mm to clear the pipe and the obstruction.
2.- Introduce the spring (A) by hand into the pipe until it stops (obstruction zone). Select an
appropriate drill and securely connect it to the soft shaft (E). Push the drill along slider slot of the
shaft to engage. This makes connection more reliable, easy and fast. To remove the soft shaft,
insert the key and push the shaft with both hands in direction opposite to the T slot of the
terminal to remove the shaft. It saves time and manpower.
3.- Steps 2 and 3 must be followed until the pipe is totally clean.
4.- Once the pipe is totally clean, extract the spring (A) by hand into the machine taking care not
to introduce water or any other form of contamination into the machine.
5.- Switch off the machine (select "OFF" position).
6.- Unplug it of the mains.
For using spring with any of the accesories shown on page 5, spring must be introduced by hand
into the inner space of the machine.
ELECTRIC PIPE CLEANER 20-110 mm