Installation manual
Daikin room air conditioner
FTXP50M2V1B
FTXP60M2V1B
FTXP71M2V1B
FTXF20A2V1B
FTXF25A2V1B
FTXF35A2V1B
FTXF50A2V1B
FTXF60A2V1B
FTXF71A2V1B
ATXF50A2V1B
Installation manual
ATXF60A2V1B
English
Daikin room air conditioner
ATXF71A2V1B

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Daikin FTXP50M2V1B

  • Página 1 Installation manual Daikin room air conditioner FTXP50M2V1B FTXP60M2V1B FTXP71M2V1B FTXF20A2V1B FTXF25A2V1B FTXF35A2V1B FTXF50A2V1B FTXF60A2V1B FTXF71A2V1B ATXF50A2V1B Installation manual ATXF60A2V1B English Daikin room air conditioner ATXF71A2V1B...
  • Página 2 3P511700-8C...
  • Página 3 3P511700-2A...
  • Página 4 3P511700-3A...
  • Página 5 3P511700-7B...
  • Página 6 3P511700-9D...
  • Página 7: Tabla De Contenido

    Daikin website (publicly accessible). Installing the indoor unit ............5.2.1 To install the mounting plate ........▪ The full set of latest technical data is available on the Daikin Business Portal (authentication required). 5.2.2 To drill a wall hole ............10 5.2.3...
  • Página 8: Preparation

    2 Install 2 screws (class 20~35) or 3 screws (class 50~71) back manner. on the front grille. 3 Install the air filter and then mount the front panel. Installation manual FTXP50~71M2V1B + FTXF20~71A2V1B + ATXF50~71A2V1B Daikin room air conditioner 3P512025-8R – 2019.12...
  • Página 9: To Remove The Electrical Wiring Box Cover

    5 To re-install the cover, first hook the bottom tab onto the plate pocket. electrical wiring box, and slide the cover into the 2 upper tabs. 116.5 (mm) FTXP50~71M2V1B + FTXF20~71A2V1B + ATXF50~71A2V1B Installation manual Daikin room air conditioner 3P512025-8R – 2019.12...
  • Página 10: To Drill A Wall Hole

    ▪ Pipe length. Keep drain piping as short as possible. ▪ Pipe size. If drain hose extension or embedded drain piping is required, use appropriate parts that match the hose front end. Installation manual FTXP50~71M2V1B + FTXF20~71A2V1B + ATXF50~71A2V1B Daikin room air conditioner 3P512025-8R – 2019.12...
  • Página 11 To check for water leaks 2 Wrap the drain hose and the refrigerant pipes together using 1 Remove the air filters. insulation tape. FTXP50~71M2V1B + FTXF20~71A2V1B + ATXF50~71A2V1B Installation manual Daikin room air conditioner 3P512025-8R – 2019.12...
  • Página 12: Connecting The Refrigerant Piping

    Do NOT connect the power supply to the indoor unit. This Terminal block could result in electrical shock or fire. Electrical component block Cable clamp 5 Strip the wire ends approximately 15 mm. Installation manual FTXP50~71M2V1B + FTXF20~71A2V1B + ATXF50~71A2V1B Daikin room air conditioner 3P512025-8R – 2019.12...
  • Página 13: Finishing The Indoor Unit Installation

    ▪ Do NOT push the refrigerant pipes onto the bottom Drainage frame or the front grille. Make sure drainage flows smoothly. Possible consequence: Condensate water might drip. FTXP50~71M2V1B + FTXF20~71A2V1B + ATXF50~71A2V1B Installation manual Daikin room air conditioner 3P512025-8R – 2019.12...
  • Página 14: To Perform A Test Run

    Daikin website (publicly accessible). Prerequisite: Power supply MUST be in the specified range. ▪ The full set of latest technical data is available on the Daikin Prerequisite: Test run may be performed in cooling or heating Business Portal (authentication required).
  • Página 15 Receiver Limit switch Float switch S*NPH Pressure sensor (high) S*NPL Pressure sensor (low) S*PH, HPS* Pressure switch (high) S*PL Pressure switch (low) Thermostat S*RH Humidity sensor FTXP50~71M2V1B + FTXF20~71A2V1B + ATXF50~71A2V1B Installation manual Daikin room air conditioner 3P512025-8R – 2019.12...