DAYLIGHT CONTROL
i
5
100 hours burn-in pushbutton
I / II selector for
1
2
delay timer
occupancy/daylight
harvesting modes
4
light detection
3
movement detection
1
presence detection ON
daylight regulation OFF
max light out if presence
detected ( DEFAULT SETTING )
presence detection ON
daylight regulation ON
if presence is detected: light output
according to setting daylight sensor
2
set delay time (minutes) between last moment of
presence detection and starting the
"Exit" sequence
Settings
15
1
presence
default
detection
The sensor will automatically lengthen the delay time
!
when the sensor detects presence directly after the
moment it has given the signal "no presence" (will
double the delay time once), this to reduce the anno-
yance of false "no presence" triggers.
3
movement sensor PIR ( Passive Infra Red )
10 m
reacts on movement by means of a
temperature difference like the
human body.
4
setting light detection
+ = more photosensitivity
- = less photosensitivity
absolute position
30 min
1m
exit sequence
minimum level
5
5
H = 1,86 m
1,3m
8
activate / deactivate the 100 hours burn
in sequence.
Must be activated each relamping.
ACTIVATE
1-2 sec
1x
respond
no possibility to dim the lights
no presence detection
no daylight regulation
DEACTIVATE
> 3 sec
2x
respond
> 100h burn in sequence
MIN 1 m
Delta Light
®
/ www.deltalight.com / Last Update 25/06/2012