Lightmates
Instructions
Please read these instructions fully before using these adaptors.
Refer to instruction manual
Always ensure that the test leads are connected to your instrument be-
fore the adaptor and disconnect from the adaptor before the instrument.
These adaptors can be used in conjunction with a wide variety of test
equipment that uses test leads terminating in 4mm safety connectors.
These adaptors enable a range of safety tests to be conducted on light
fitting terminals reducing or eliminating the need to hold test probes in
place.
Warning: These adaptors should only be used for testing purposes and
should not under any circumstances be used to connect other types of
equipment to a mains supply.
Pre-use check: Before each use the adaptor should be inspected to
ensure that it is not damaged in any way. If any damage is noticed the
adaptor should be withdrawn from service and replaced.
To use simply select the appropriate adaptor for the type of fitting to be
tested. With power to the fitting turned off attach the adaptor securely to
the light fitting. Your instrument's test leads should firstly be connected to
your instrument and then attached to one or both of the adaptor's 4mm
test sockets as the test requires, and then the test conducted.
The terminals on the ES and SES versions are colour coded. The red
/ brown marked terminal connects to the centre (live) terminal in the
ES light fitting. The blue / grey terminal connects to the screw thread
(neutral) of the ES fitting.
Cleaning Instructions
To clean the adaptors wipe with a damp cloth. Use a mild soap (non
detergent) if required. Take care not to allow ingress of water into the
electrical connections and allow to dry thoroughly before reconnecting
or use.
General
If used in a manner not specified above protection may be impaired.
Max voltage 230V.a.c. Max test current for loop testing is 25A 40ms.
For Insulation testing maximum current rating is 1mA at 1000 V DC
continuous.
These adaptors are maintenance free and contain no serviceable parts.
Environmental: Suitable for use between 5ºC & 40ºC <80% RH.
Storage 0 - 40 ºC
IEC 61010-1 Cat II 300V
Measurement Category ll is for measurements on circuits directly connected to the
low voltage installation.