ARC1 Mini Mullion reader
MA1 OEM Module
Installation instructions
ARC1-XY
ARC1S-XY/PH5
ARC1S-XY/BT1
Outputs cable: 3 m
A
Use an AC/DC power supply type LPS, Limited Power Source (as per IEC/UL/EN 60950-1 Ed2) or type ES1, PS1 (according to IEC/UL/EN 62368-1) for the main supply.
Main power supply:
Max. consumption at 12 Vdc:
Communication:
RS485 (L+ & L-) / TTL (Wiegand / Clock and Data)
Connector output:
- 8 female stamped crimp terminals 28-22AWG (Wurth Electronik 62400113722DEC)
- 8 points female dual-row terminal housing (Wurth Electronik 624008213322)
(use Crimp Hand Tool WURTH ELEKTRONIK 600624228220)
Cable output:
TRANXALARM - 8x0,22mm
Protection:
IP65 classified reader
The operating mode for the Buzzer and LED 1 and 2 can be programmed by a configuration card (SCB / OCB) or controlled by the remote system with a 0 Vdc
respectively on the "Led 1", "Led 2" and "Buzzer" inputs of the reader's connector or controlled by the communication protocol of the reader (SSCP
Tearing is detected by an accelerometer. When the reader is wrenched:
•
for R/S 31: the wrenching signal will be emitted on the "Data/Data1" line. This function is configurable via a configuration card.
for R/S 33 and OSDP
▪
TM
for W33: the reader will perform the operations configured with the SSCP
▪
Caution: switch on the reader when it is in its final position to initialize the accelerometer in the correct position.
R and S readers are configurable with SCB RFID / Virtual configuration card.
OSDP
TM
readers are configurable with OCB RFID / Virtual configuration card or with FileTransfer command.
If the SCB/OCB is compatible with the reader's firmware, the LED lights green and the buzzer beeps five times.
▪
If the SCB/OCB is not compatible with the reader's firmware, the LED lights red and the buzzer is activated for 1 s.
▪
If the SCB/OCB key is different from the reader's key: no reaction.
▪
Caution: set your reader with your own company key.
On power-up, the reader enters an initialization phase:
1.
Activation of the white LED and buzzer for 100 ms.
For read-only readers and OSDP
2.
Activation of the LED, according to the color code: Red = +10, Orange = +5, Green = +1, indicating the firmware version.
3.
For serial R/S reader only: the orange LED flashes 20 times: waiting for an update.
4.
For Bluetooth
reader only: Activating white fixed LED during Bluetooth initialization.
®
5.
Activation of the default LED (read-only: flashes blue, OSDP
Caution: at the reader Bluetooth (BT1) powering, make sure that nothing is in an area of at least 10 cm / 3.94 in. around the reader (ex. No hand
in front of the reader...).
Connection
- Press the orange part to open.
- Insert the wire.
- Release the orange part.
- Check that the wire is correctly clipped.
▪ The supply voltage at the reader's connector should be between +9 Vdc and +15 Vdc.
▪ As far as possible, keep the reader away from computer or power source cables. They can generate electrical interference, depending on their radiation level and
the proximity of the reader.
▪ Recommended distance between two readers: parallel plane: 15.8 in – same plane: 15.8 in – perpendicular plane: 11.8 in.
▪ Recommended distance between two Bluetooth
▪ Place the reader at a height of less than 2 meters / 78.74 inch (standard UL/IEC 62368).
▪ If the reader is fixed on a metal surface, it is possible to have a reduction in the reading distance.
▪ Use a ferrite (two-way) for the cable (power supply and data). Example: reference 74271222 WURTH ELEKTRONIK.
▪ By design, the reader can be installed indoors and outdoors.
▪ BEFORE powering on, connect the wires or the connector of the reader. Before disconnecting the wires or the connector of the reader, power off.
▪ Operating temperature: -4 °F to 158 °F / -20°C à +70°C.
STid reserves the right to make change without notice, for the purpose of product improvement.
Lecteur Etroit ARC1
Module OEM MA1
Notice d'installation
MA1-XY
MA1S-XY/PH5
MA1S-XY/BT1
B
Range: +9 Vdc to +15 Vdc
ARC1-XY: 130 mA
ARC1S-XY /PH5: 140 mA
MA1-XY: 130 mA
MA1S-XY /PH5: 140 mA
– Length 3.05m
2
: the reader will perform the operations configured with the configuration card.
readers:
TM
readers: 2 meters / 78.74 inch either plan.
®
© STid - 20 PA des Pradeaux FR13850 Gréasque - NI1110A09- Page 1 sur 6 - Ed. 02/07/2021
Lector Estrecho ARC1
Módulo OEM MA1
Procedimiento de instalación
conforme con NOM-024 -SCFI-2013
Product references
X:
1: TTL Output
3: RS485 Output
Power supply characteristics
Typical: 12 Vdc
ARC1S-XY /BT1: 150 mA
MA1S-XY /BT1: 150 mA
Characteristics
Buzzer / LED
Anti-tearing
protocol.
®
Read-only reader configuration
Powering-up the readers
: off; if no customer specific configuration).
TM
Caution for Bluetooth reader
TBLOCK option
Host
Precautions for installation
Y:
A: cable
B: cable with connector
Connector Output cable
Wiegand Clock & Data RS485
4
Brown
5
Red
2
Grey
1
Blue
6
Yellow
Clock
3
Green
8
Orange
7
White
0.94 in
US
FR
ES
Type
0 Vdc
+Vcc (+9 Vdc to +15 Vdc)
D0
Code
NC
D1
Data
L+
Clock
L -
Led 1
Led 2
Buzzer
®
/ OSDP
TM
).
➔Reader