Testing The Safety Assembly Module; Technical Data; Dimensions And Connections; Electric Circuit Diagram - Blanco 4L EU Instrucciones De Uso Y De Montaje

Ocultar thumbs Ver también para 4L EU:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 45
EN
CLEANING, CARE, MAINTENANCE
12.2

Testing the safety assembly module

The safety valve must be checked every six months to ensure it functions
correctly. To do so, briefly turn the cap on the pressure control valve in the
safety assembly through about 90°. This opens the valve and water will flow
into the drain. Ensure that the drain is correctly installed and the water can
drain away correctly. No more water must come out after you release the cap.
If this is not the case, the pressure control valve no longer shuts correctly and
the safety assembly needs to be replaced.
13.

Technical data

13.1

Dimensions and connections

Mains cable
EU: Types E+F CEE 7/7 Schuko safety plug
UK: Type G / BS 1363 British 3 pins (13 A fuse)
Cold water inlet connection
G 1/2" internal thread
Hot water outlet connection
G 3/8" external thread
350 mm
24
ø 229 mm
337 mm
UK
Art.-Nr: 525 788
EU
Art.-Nr: 525 233
1600 mm
800 mm
CLEANING, CARE, MAINTENANCE
13.2

Electric circuit diagram

3
L
N
PE
1 Temperature limiter
2 Temperature sensor
3 Heating element
4 Electronics
5 Operation
6 LED display
1
2
4
5
6
EN
25

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

4l uk

Tabla de contenido