CONFIGURATION
QNUBU
-Temperature setting:
Press the SET button
buttons
-Time settings:
Press the SET button
buttons
-Confirm settings: After finishing setting the time and temperature you
must press SET
The plates will start to heat up
-Countdown: After closing the plates, press the countdown start
button.
PRESSURE RELEASE VALVE ADJUSTMENT:
pressure with the hydraulic jack CLOSE the pressure release valve turning to the RIGHT. Then
the system will be ready to apply pressure.
IMPORTANT: Apply the pressure smoothly once the pressure limit is reached, do not force the
machine. May cause oil leaks and hydraulic system failure NOT covered by warranty.
To realease pressure on the plates, OPEN the pressure release valve by turning it to the LEFT.
The hydraulic system will release the pressure and the plates will open automatically.
TIME
TEMPERATURE & TIME SETTING:
Set button
1 time, the display shows "SP", then use the
to increase or decrease.
1 time, the display shows "ST", then use the
to increase or decrease the pressing time.
again to confirm settings.
CLOSE
OPEN
TEMPERATURE
HOME SCREEN
CONF. TEMP.
Increase
Decrease
button
button
Before applying
DO NOT FORCE THE PRESS!
IF YOU TRY TO APPLY MORE PRESSURE
MAY DAMAGE THE PRODUCT.
CONF. TIME
Countdown
button