Safety
The drive may only be used when built in and only in conjunction with the DGD-Intelligent-Spindle or with a
built-in nutrunner of the Modular-Tightening-System.
All operators must be trained and experienced before operating.
The local safety regulations for installation, operation, and maintenance must always be followed.
Code
1WK1M
1WK2M
2WK1M
2WK2M
3WK1M
3WK2M
4WK1M
4WK2M
4WK3M
1) see graph
NOTE
When measuring torque and angle signals directly at the transducer, these measuring devices must be gal-
vanically separated from the protective earth conductor (PE, e.g. use oscilloscope with insulation transfor-
mer). Observe that the two 0 V references (0 V TQ/Pin D and 0 V supply/Pin E) are not shorted. lf this is
not observed, failures and measuring errors in torque measurement may occur.
Max. cable length: 50 m. Min. cross section of cable: 0,14 mm²
Repair and Assembly
NOTE
Return complete offset drive to Apex Tool Group for repair. Any tampering with the drive can cause erro-
neous results and will void the warranty.
CAUTION!
When the drive is built into the nutsetter, the tightening torque has to be observed for the union nut. See
Maintenance and Assembly Instruction.
NOTE
Grease before mounting with other modular components.
see Fettsorten • Grease lubricants • Sortes de graisses • Lubrificanti • Tipos de grasa • Tipos de graxa,
page 14
1712wec_en.fm, 08.10.2014
EN
Order no.
Capacity
934360
934361
934370
934371
934380
934381
934390
934391
934392
A
P1712A/WE 2014-10
1)
A
Nm
Order no.
35
900008 (2×)
60
110
900008 (2×)
170
200
917210 (2×)
300
400
500
917253 (4×)
660
...WK...M