Installation Instructions for the Vision Sensor SIMATIC
VS130-2 and VS130-2vcr
Information in Addition to the Installation Instructions
Apart from these installation instructions, you should also read Getting Started, the online
helps and the Vision Sensor SIMATIC VS130-2/VS 130-2vcr manual on the supplied CD.
Steps in Installation
Step
Activity
1a
Arrange the sensor head so that reflections are kept to a minimum. The angle of its central
axis should be typically 15 ° from vertical (angle α) (permitted range of angles: 0 ≤ α ≤ 40° ).
Vision Sensor SIMATIC VS 130-2/VS 130-2vcr - Installation Instructions
A5E00475766-01
Sensor head
Ring flash
α
Object with code
Conveying unit
Step
Activity
1b
If there is still too much reflection at an angle of 15°, select an arrangement in which the
sensor head and the ring flash are not concentric.
Note:
The mechanism for mounting the ring flash is not supplied with the product.
If the ring flash does not meet your requirements, please contact your sales partner who will
be able to recommend other suppliers of lighting for the VS130-2/VS 130-2vcr.
Fastening
bracket
Ring flash
Sensor head
Object with code
Conveying unit
1