06.2 LOWER LIMIT SWITCH BY PRESSURE - UPPER LIMIT SWITCH BY NO PRESSURE
Connect the power supply
1-
Bring the roll-up shutter in a intermediate position
2-
Move briefly the roll-up shutter downward
3-
Press together UP and DOWN until the motor makes two alternate
4-
movements (circa 5 secondi), then release the buttons
Press and hold DOWN until the motor stops automatically on the
5-
lower limit switch by pressure
Bring the motor to the desired upper limit switch
6-
Press together UP and DOWN until the motor makes two alternate
7-
movements (circa 5 secondi), then release the buttons.
(*) until the installation procedure is finished, the movement of the motor is preceded by a small click
06.3 LOWER LIMIT SWITCH BY NO PRESSURE - UPPER LIMIT SWITCH BY PRESSURE
Connect the power supply
1-
Bring the roll-up shutter in a intermediate position
2-
Move briefly the roll-up shutter downward
3-
Press together UP and DOWN until the motor makes two alternate
4-
movements (circa 5 secondi), then release the buttons
Bring the motor to the desired lower limit switch
5-
Press together UP and DOWN until the motor makes two alternate
6-
movements (circa 5 secondi), then release the buttons
Press and hold UP until the motor stops automatically on the upper
7-
limit switch by pressure
(*) until the installation procedure is finished, the movement of the motor is preceded by a small click
NOTE: to optimize the behavior near the upper limit switch, read section 09 "Early stop" and 10 "Close pressure»
*