4.
Start-up
After switching on the supply voltage:
1. a display test is carried out
(Duration: 2 seconds)
2. Device type and software
version are displayed
(Duration: 2 seconds)
5.
Programming
5.1
Switching to programming
To switch to the programming mode:
1. switch the power supply of the device off, press
simultaneously both keys on the front side, and then
switch the power supply on again.
⇑
⇑
2. The display shows the following message.
5.2
Changing the parameter setting
1. press the right-hand/grey key to change the
parameter setting by one value at a time
⇑
2. to input numerical values, select first the decade with
the left-hand/red key
⇑
3. the decade blinks
5.3
Saving the parameter setting and
switching to the following parameter
1. keep the left/red key pressed
⇑
3. the selected probe is
displayed
(Duration: 2 seconds).
4. the display is ready to
operate and the measured
value is displayed.
3. release both keys. The first parameter to be set
appears on the display. The display switches every
second between the following messages
1 s
4. press the left key to stop the display from
switching. The last programmed parameter setting
is displayed.
4. set now the numerical value using the right-
hand/grey key
⇑
5. to reach the following decade, press the left-
hand/red key
⇑
6. if negative numerical values are required, set the left
decade to "–" or "–1".
2. and press simultaneously the right/grey key.
⇑
15