EN
The Minimum Size Equipment Conductors for the AC mains required are 14 AWG if made of Copper or 12
AWG if made of Aluminium or Copper-Clad Aluminium. Do not use any switch-controlled outlets to power
the system. The system is to be connected to a 15A receptacle or circuit.
For PERMANENTLY CONNECTED EQUIPMENT, a readily accessible disconnect device shall be incorporated
external to the equipment.
AC Terminal Fuse
The following steps are only presented in case you need to replace the AC terminal fuse.
1. Disconnect the AC power cord from the power source or for permanent installation, turn off the power
breaker
.
1
2. Open the AC compartment at the top left to access the fuse holder.
3. Pull out the fuse holder.
4. Replace the fuse using the same fuse type:
250VAC, 2.5 A, Time Lag, Slow Blow,
Operating Temperature: -55
Permitted replacements:
5. Replace the fuse holder in its location.
6. Close the AC compartment.
7. Connect the AC power cord to the power source or for permanent installation, turn on the power
breaker
.
1
.For permanent installation, this step must be done by a qualified technician in accordance with your
1
local safety regulations.
PoE+ Power Supply Diagram (A22KPOE)
The PoE+ splitter to DC power supply is pre-installed in the A22KPOE box but needs to be connected to the
PCB. Simply plug the two pin terminal to the input power supply.
PoE+S Splitter Features:
Interface
• 2-Port RJ-45 interfaces
- 1-Port Data + Power input
- 1-Port Data output
• 1-Port DC output power socket
• Output set to 24V DC (DIP switch)
Do not power up the A22POE until all connections are completed.
High Security Access Control 2-Doors Module
C to +125
C .
o
o
Power over Ethernet
• Ultra Power over Ethernet End-Span / Mid-Span PSE
• IEEE 802.3at/af PoE standard compliant
• Supports 56VDC, 50pwatt PoE power output
• Splits the 56V DC power over RJ-45 Ethernet cable into 24V DC
• Remote power feeding up to 100 meters
A22K
Fuse holder
output
51