INSTRUCTIONS IN ENGLISH | SC-5 UNIVERSAL FLOW METER
DEMO VIDEO:
YOUTUBE.COM
SEARCH:
SpotOn SC-5 Universal Flow Meter
METER COMPONENTS:
1
Pop-Up Rubber Funnel
2
Lanyard Ring
3
LCD Display
4
Power Button
5
Battery Cover
USE OF PRODUCT:
Taking a Measurement
Sinks
Vanities
Fig. 2
Fig. 3
02
2
3
4
5
Fig. 1
Showers
Ag Spray Nozzles
Fig. 4
Fig. 5
SpotOn® SC-5 Universal Flow Meter Item #38580
INSTRUCTIONS IN ENGLISH | SC-5 UNIVERSAL FLOW METER
Taking a Measurement (continued)
Expand or collapse the rubber funnel as needed (See Fig. 2). Press the POWER button to turn the
meter on. The LCD will flash "000" momentarily before showing "- - -", which indicates the meter
is ready to take a new measurement. Once the display shows "- - -" it can be placed under the
1
faucet/shower/spray nozzle to be tested (See Fig. 3). There is a 60 second timeframe to place the
meter under the flow from the time "- - -" is first displayed. Placement of the meter under the flow
should be brisk and precise so that all the flow is quickly transferred into the meter. As the meter
fills with water, the display will start flashing "- - -", which indicates the reading is in progress. As
soon as water reaches the meter's upper sensor, the flashing stops, and the flow rate is calculated
and displayed for 90 seconds or until the POWER button is pressed to start a new reading (See
Fig. 4). Once the reading is displayed, the meter can be emptied at any time by tipping the meter
upside down to pour the water out through the top (See Fig. 5). If a reading needs to be restarted,
simply empty the meter and press the POWER button to begin a new reading cycle. PLEASE NOTE:
The most accurate measurements are made with the meter held steady during the fill process.
Turing The Meter ON/OFF
The meter will turn on any time the POWER button is pressed. The meter can be shut off by
pressing and holding the POWER button for 3 seconds or waiting for automatic shutoff after 90
seconds of inactivity.
Changing Measurement Units
The meter can be configured to display readings in either
gallons per minute (GPM), liters per minute (LPM), or
liters per hour (L/hr). To change the display units, the
user must first turn the meter off. Then press and hold the
POWER button until the display is blank except for the
units of measure, about 3-5 seconds (See Fig. 6). When
the display shows only the units of measure, release the
POWER button and the display will start flashing the currently selected unit of measure. Press the
POWER button to change this selection. Once the correct unit type is selected and flashing, wait
without pressing the button for 5 seconds. The meter will automatically save the new setting and
shut off.
SpotOn® SC-5 Universal Flow Meter Item #38580
Fig. 6
03