4259860000_IS_MCZ_CCC.qxd:425986
9.
Technical Data
Input
Input voltage
Operating current
Voltage drop
Input overload capacity
Output
Load
Adjustment period (T99)
Residual ripple
General data
Chopper frequency
Transmission errors
Temperature effect
Test voltage
Input / output
2)
EMC
Ambient temperature
Operation
Storage
1)
Medium TC in the specified operating temperature
range (-25 °C ... +60 °C)
2)
Valid for 4 ... 20 mA; minor deviations are possible
during interferences.
22
0 ... 20 mA
max. 15 V
< 100 μA
2.5 ... 3 V (at 20 mA)
max. 50 mA, 15 V
0 ... 20 mA, max. 10 V
500 Ω
approx. 5 ms for a load of 500 Ω
< 10 mV
eff
approx. 200 kHz
< 0.1 % of end value + 0.05 % of
measured value / 100 Ω load
1)
50 ppm/K from measured value
for a load of 0 Ω
510 V AC, 50 Hz
EMC directive
EN 61 326
EN 61 326/A1
-25 °C ... +60 °C
-40 °C ... +85 °C
01.12.2010