Malfunctions
Malfunction
Machine without function
Cylindrical brush is not turning
Poor suction performance
Little or no water
Technical data
Machine
Working width
Dimensions (LxWxH)
Machine weight (empty tanks)
Rated voltage
Frequency
Power supply cord length
Rated power, nominal
Fresh water tank, nominal +/- 5%
Values according to IEC 60335-2-68
Sound pressure level LpA
Uncertainty KpA
Vibration
Uncertainty K
Splash water guard
Protection class
Possible causes
Machine is switched off
No power supply
Main cord defect
Motor does not turn
Brush drive switched off
Motor does not turn
Switch not pressed
Cylindrical brush not installed cor-
rectly
Suction hose blocked
Suction hose defect
Fresh water tank filter blocked
Pump switched off
Nozzles blocked
38
109 x 47 x 94
52
230-240V~
50
15
2000
30
Troubleshooting
• Switch on the main switch
• Insert the power supply plug into
the mains socket
• Replace the main cord
• Contact your service partner
• Turn brush drive switched on
• Contact your service partner
• Press switch
• Check the cylindrical brush and in-
sert correctly if necessary
• Wash out the squeegees
• Contact your service partner
• Clean the fresh water tank filter
• Press function switch
• Clean nozzles
220V~
120V~
60
60
2000
1300
73
0.8
<2.5
0.25
IPX4
I
Page
71
EN
71
71
72
71
77
71
77
cm
cm
kg
AC
Hz
m
W
dB(A)
dB(A)
m/s2
m/s2
79