technical features
Technical data - room sensor (cabled version)
Power supply
Electrical uptake
Operating temperature
Storage temperature
Dimensions
Bus wire length and cross-sectional area
NOTE:
IN ORDER TO AVOID INTERFERENCE PROBLEMS, USE A
SHIELDED CABLE OR TWISTED PAIR CABLE.
Insulation class
Protection rating
Temperature sensor
Technical data - room sensor (wireless version)
Power supply
Battery life
Operating temperature
Frequency band used
Maximum power in the band
Receiver category
Reception range
Storage temperature
Dimensions
Insulation class
Protection rating
Temperature sensor
14 - GB
BridgeNet® BUS 8 to 24V
Power Source complies
6 mA
-0 to 40°C
-10 to 70°C
93 x 88 x 24 mm
max. 50 m - min. 0.5 mm²
III
IP30 (when installed as specifi ed)
±1%
2 x 1.5 V, LR03 (AAA) alkaline batteries
Alternatively
2 x 1.5 V, LR03 (AAA) 1200 mAh lithium bat-
teries
2 years
-0 to 40°C
868.7-869.2 MHz
< 10 mW
2
100 m - 300 m in the open, depending on
the number of devices
-10 to 70°C
93 x 88 x 24 mm
III
IP30 (when installed as specifi ed)
±1%
max / Limited