The system has 4 different regeneration cycles indicated by the codes U1 – U2 – U3 – U4.
Choose the most suitable for your application according to the size of the cylinder and to the quantity of resin it contains.
warning
IMPORTANT
The regeneration cycle is set by the manufacturer.
TIMER AND ICONS FRONTAL DESCRIPTION
DISPLAY
The display shows clearly visible 2-digit numbers.
SET UP BUTTONS
Set ups have been simplified and reduced for each function and for each single button.
MANUAL REGENERATION
It is possible to set up an additional regeneration at any time or making it start immediately by pushing the relevant button.
POSITION INDICATOR
During the regeneration process the current position is displayed.
FRONTAL CLOSING BLOCK
A special device blocks the opening of the frontal.
The buffer battery, which maintains time set up in case of black out, is not present.
The system maintains the time stored for about 6 hours and then resets.
This buttons allows setting the hour, the system does not allow to set minutes.
This button allows setting the quantity of brine needed for resin regeneration.
This setting is made by the manufacturer.
This button allows setting the regeneration break.
It is possible to choose a regeneration break every 8 working hours (3 regenerations per day) up to a regeneration every 30
days.
The regeneration time of reference is 2:00 a.m.. In case of 3 regenerations per day, these will start at 2:00 a.m., 10:00 a.m.
and at 6:00 p.m., while in case of 2 regenerations per day, these will start at 2:00 a.m. and at 2:00 p.m.