Ocultar thumbs Ver también para Heritage Serie:

Publicidad

Enlaces rápidos

Customer Service
(Servicio al cliente)
1-800-437-0784
6400 E. 11 Mile Rd.
Warren, MI 48091-4101
Includes 12'x12' (366x366 cm), 12'x16' (366x488
cm), 12'x20' (366x610 cm), 12'x24' (366x732)
- BEFORE YOU BEGIN -
Tools required
First...
(Herramientas
Check with your local building authority before erecting.
necesarias)
Read instructions thoroughly before you begin.
❑ Hammer
Building Codes
(Martillo)
Our buildings are designed to meet most local and national
❑ Phillips
U.S. codes and are not meant to be used for living space.
Screwdriver
General construction drawings can be provided.
Stamped certified drawings can be provided for a fee.
(Desarmador cruz)
Call for details.
❑ Level
Check All Parts
(Nivel)
If a part is missing, circle the part in question and call.
❑ Ladder
Please note the primer color may vary on siding and
(Escalera)
trim parts. This is a factory applied primer intended for
❑ Pencil
preparing your building for painting. This is NOT a finish
coat. This primer color variation will not affect the look of
(Lápiz)
your building once painted.
❑ Tape Measure
Important
(Cinta métrica)
Lumber is graded from one side, use most attractive
❑ Utility Knife
face to the outside.
In a drawing, a dotted line represents a part hidden from
(Navaja)
view (like a part under a panel).
❑ Paint Tools
Assistance required
(Herramientas
Assistance is necessary to handle, fit, and secure
para pintar)
some components.
❑ Caulk Gun
Squareness is very Important!
(Pistola para
Keep 90° corners and 90° perpendiculars throughout
masillado)
the assembly to ensure all components fit together.
❑ Hand Saw
Check foundation size
(Sierra portátil)
Before starting on your foundation, make sure you are
❑ Wood Glue
building the correct size foundation for your building.
(Pegamento para
Always wear OSHA-APPROVED safety
glasses throughout assembly process
madera)
Optional Tools
(Herramientas
)
opcionales
❑ Electric Drill w/
#2 Phillips Tip
(Taladro eléctrico
Broca "Phillips")
❑ Chalk Line
(Línea de marcar)
❑ Square
Base +3
(Escuadra)
Extenders/
Extensiones
❑ Nail Pouch
12'x24'
(Bolsillo para
(366x732 cm)
clavos)
We manufacture kits from select construction grade lumber and engineered wood products. Construction grade
lumber, a product cut from trees, has many natural characteristics and blemishes that may be present in some of
the pieces you receive in your kit. Natural characteristics and blemishes in construction lumber may include knots,
torn wood grain along edges, minor cracks/splits, twists, limited bark along edges and pitch pockets that may
exude sap. Be assured that the individual parts have been cut and inspected to remove as many of the wood's
natural, less appealing characteristics as possible. These characteristics and/or blemishes will not affect the
strength, durability, or structural integrity of the finished product. Generally, the exterior trim parts selected for
your kit are graded from only one side and should be installed with the most attractive side outward. Our limited
warranty does not cover the natural characteristics and blemishes that occur with construction grade lumber
products.
Heritage / Premier Series
12' Wide Gable
Techo a dos aguas 12'
Instrucciones para edificios de 12'x12' (366x366 cm), 12'x16'
(366x488 cm), 12'x20' (305x610 cm), 12'x24' (366x732)
Base +2
Extenders/
Extensiones
Base +1
12'x20'
Extenders/
(366x610 cm)
Extensiones
12'x16'
(366x488 cm)
Fabricamos nuestros equipos de madera elaborada y de productos maquinados de madera. La madera
elaborada, producto de árboles, tiene muchas características e imperfecciones naturales que puedan
tener algunas piezas contenidas en el equipo. Estas imperfecciones y características pueden incluir
nudos, grano rasgado sobre el borde, rajas/grietas pequeñas, torsiones, cortezas en el borde, y bolsos
que exuden savia. Asegurams que hemos cortado e inspeccionado las partes individuales para eliminar
las características naturales menos atractivas posibles. Estas características y/o imperfecciones no
afectarán la fuerza, durabilidad ni la integridad estructural del producto final. Po lo general, las piezas de
moldura exterior seleccionadas para su equipo se elaboran de un solo lado y deben ser instaladas con
la parte más atractiva por fuera. Nuestra garantía limitada no cubre las características e impefecciones
que ocurren con los productos de madera elaborada.
#16608
- ANTES DE EMPEZAR -
Primero...
Consulte la autoridad de construcción local antes de
construir el edificio.
Lea las instrucciones completamente antes de empezar.
Códigos de Construcción
Hemos diseñado nuestros edificios a que conformen con
todos los códigos de construcción locales y nacionales. Los
edificios no están proyectados como residencia.
Se disponen planes generales de construcción.
Se disponen de planes certificados por un precio. Estos
planes no garantizan la aprobación de los autoridades
locales.
Compruebe todas las piezas
Si falta una pieza, indícala con un círculo y llámenos.
Aviso: El color del imprimador puede variar en la covertura
y las partes de la moldura. Este imprimador se aplica en la
fábrica y es para preparar su edificio para pintar. NO es una
capa de pintura terminada. La variación en el color del
imprimador no afectará la apariencia de su edificio al pintarlo.
Importante
La Madera está elaborada en un solo lado. Use el lado más
atractivo en el exterior.
Si falta una pieza, póngale un círculo y llámenos.
En un dibujo una línea punteada representa una pieza no
vista (por ejemplo, una pieza debajo de un panel)
Ayuda requerido
Seleccione un sitio nivelado.
Será necesario pedir ayuda para manejar, unir, y reforzar
algunas piezas.
¡Es preciso escuadrar el edificio!
Mantenga ángulos de 90° en las esquinas y los
perpendiculares durante la construcción para asegurar que
todas las piezas se unen correctamente.
Comprueba las dimensiones de la
cimentación.
Compruebe que las dimensiones de la cimentación son las
correctas para el edificio.
Siempre lleve gafas de seguridad
aprobadas por OSHA durante la
construcción.
05/11/05
Made in the USA
Hecho en Estados Unidos
Base
Building/Edificios
12'x12'
(366x366 cm)

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Backyard Storage Solutions Heritage Serie

  • Página 1 #16608 05/11/05 Heritage / Premier Series Customer Service (Servicio al cliente) 12’ Wide Gable 1-800-437-0784 6400 E. 11 Mile Rd. Made in the USA Techo a dos aguas 12’ Warren, MI 48091-4101 Hecho en Estados Unidos Includes 12’x12’ (366x366 cm), 12’x16’ (366x488 Instrucciones para edificios de 12’x12’...
  • Página 2: Parts List

    12’ x 12’ (366 x 366 cm) 12’ X 12’ (366 x 366 cm) PARTS LIST LISTA DE PIEZAS 3/8”x48”x84” 3/8”x15-7/8”x84” 3/8”x23-7/8”x84” 3/8”x11-7/8”x32” 2x6x92-1/2” (235 cm) (.9x122x214 cm) (.9x40x214 cm) (.9x61x183 cm) (.9x30x82 cm) 2x4x94-1/2” 2x4x80” 2x6x48” 2x4x92-1/2” (240 cm) (173 cm) (122 cm) (235 cm)
  • Página 3: Dimensiones De La Madera

    68-1/2” Metal Door Edge “T” 68-1/2” Metal Door Edge “L” Left Puerta Puerta Right Door izquierda derecha (174 cm) (174 cm) Door 2”x4”x68-1/2” 1”x4”x35-1/4” 1”x4”x35-1/4” 1”x4”x14” (5x10x174 cm) (2.5x10x91 cm) (2.5x10x91 cm) (2.5x10x36 cm) 12’ X 12’ (366 x 366 cm) 12’...
  • Página 4: Lista De Piezas De Extensión

    12’ X 12’ (366 x 366 cm) 12’ X 12’ (366 x 366 cm) EXTENDER PARTS LIST LISTA DE PIEZAS DE EXTENSIÓN 3/8”x48”x84” 3/8”x23-7/8”x84” 2x6x48” 2x4x80” 2x4x48” (.9x122x214 cm) (.9x61x214 cm) (5x17x122 cm) (204 cm) (122 cm) 1x4x96” 7/16”x32”x48” 7/16”x47-7/8”x48” (1.1x78x122 cm) (244 cm) (1.1x122x122 cm)
  • Página 5: Opciones Para La Cimentación

    OPCIONES PARA LA CIMENTACIÓN FOUNDATION OPTIONS (Not supplied with kit) (No incluidas) HAY QUE CONSTRUIR EL EDIFICIO SOBRE UN BASE YOU MUST ASSEMBLE YOUR BUILDING ON A DE MADERA O DE CONCRETO. WOOD FLOOR OR CONCRETE SLAB. SITE PREPARATION PREPARACIÓN DEL SITIO •...
  • Página 6 Antes de continuar determine la Before proceeding, determine posición de la puerta y STOP desired door location and STOP construya el muro con la puerta build door wall first. primero. CONSTRUYA LOS NÚMEROS DE LOS BUILD WALL NUMBERS SPECIFIED MUROS ESPECIFICADOS WALL NUMBER EQUALS PAGE NUMBER EL NÚMERO DEL MURO CORRESPONDE AL NÚMERO DE LA PÁGINA.
  • Página 7 Antes de continuar determine la Before proceeding, determine posición de la puerta y STOP desired door location and STOP construya el muro con la puerta build door wall first. primero. CONSTRUYA LOS NÚMEROS DE LOS BUILD WALL NUMBERS SPECIFIED MUROS ESPECIFICADOS WALL NUMBER EQUALS PAGE NUMBER EL NÚMERO DEL MURO CORRESPONDE AL NÚMERO DE LA PÁGINA.
  • Página 8 IMPORTANT!!! IMPORTANTE!!! Building Tip Consejo ES PRECISO ALINEAR LOS PANELES DE LOS YOUR BUILDING CAN BE CONFIGURED IN A MUROS Y DEL TECHO ANTES DE CLAVARLOS VARIETY OF WAYS. BEFORE ERECTING WALLS, REFER TO PAGE 5 TO ENSURE YOU BUILT THE COMPLETAMENTE PARA ASEGURAR LA RIGHT WALLS FOR YOUR BUILDING.
  • Página 9 IMPORTANT!!! IMPORTANTE!!! Building Tip Consejo ES PRECISO ALINEAR LOS PANELES DE LOS YOU MAY NEED TO RACK YOUR WALL PANELS MUROS Y DEL TECHO ANTES DE CLAVARLOS AND ROOF PANELS TO ENSURE SQUARENESS COMPLETAMENTE PARA ASEGURAR LA BEFORE COMPLETELY NAILING ESCUADRA.
  • Página 10 3”(7.6 cm) VIGA HEADER x 28 STOP! DO NOT BUILD DOOR FRAMING AT THIS POINT. USE AS A REFERENCE ONLY 9-1/2” 24” 24” 9-1/2” (24cm) (61cm) (61cm) (24cm) Side View UY x7 Header 80” (204cm) 64” (163cm)
  • Página 11 3”(7.6 cm) x 74 WALL #11 MURO #11 2”(5 cm) x 152 UL x2 SP x2 9-1/2” 24” 24” 9-1/2” (24cm) (61cm) (24cm) (61cm) TK x6 UY x7 HEADER 83” (211cm) Overhead View REPEAT FOR 24” 16” 64” 16” 20-1/2” ALL SPLICES (61cm) (41cm)
  • Página 12 3”(7.6 cm) x 74 WALL #12 MURO #12 2”(5 cm) x 152 Overhead View UL x2 SP x2 REPEAT FOR 9-1/2” 24” 24” 9-1/2” (24cm) (61cm) (61cm) (24cm) ALL SPLICES TK x6 UY x7 HEADER 83” (211cm) 16” 16” 24” 20-1/2”...
  • Página 13 3”(7.6 cm) x 74 WALL #13 MURO #13 2”(5 cm) x 152 Overhead View REPEAT FOR ALL SPLICES UL x2 9-1/2” 24” 24” 9-1/2” (24cm) (61cm) (61cm) (24cm) TK x6 SP x2 UY x7 HEADER 83” (211cm) 12-1/2” 24” 24” 16”...
  • Página 14 3”(7.6 cm) x 34 WALL #14 MURO #14 2”(5 cm) x 135 Overhead View REPEAT FOR UL x2 ALL SPLICES TK x7 SP x2 83” (211cm) 24” 24” 24” 24” 24” 20-1/2” (61cm) (61cm) (61cm) (61cm) (61cm) (52cm) 140-1/2“ (357cm) 48”...
  • Página 15 3”(7.6 cm) x 90 WALL #15 MURO #15 2”(5 cm) x 184...
  • Página 16 3”(7.6 cm) x 90 WALL #16 MURO #16 2”(5 cm) x 184...
  • Página 17 3”(7.6 cm) x 90 WALL #17 MURO #17 2”(5 cm) x 184...
  • Página 18 3”(7.6 cm) x 52 WALL #18 MURO #18 2”(5 cm) x 180...
  • Página 19 3”(7.6 cm) x 106 WALL #19 MURO #19 2”(5 cm) x 257...
  • Página 20 3”(7.6 cm) x 106 WALL #20 MURO #20 2”(5 cm) x 257...
  • Página 21 3”(7.6 cm) x 106 WALL #21 MURO #21 2”(5 cm) x 257...
  • Página 22 3”(7.6 cm) x 68 WALL #22 MURO #22 2”(5 cm) x 215...
  • Página 23 3”(7.6 cm) x 120 WALL #23 MURO #23 2”(5 cm) x 264...
  • Página 24 3”(7.6 cm) x 120 WALL #24 MURO #24 2”(5 cm) x 264...
  • Página 25 3”(7.6 cm) x 120 WALL #25 MURO #25 2”(5 cm) x 264...
  • Página 26 3”(7.6 cm) x 88 WALL #26 MURO #26 2”(5 cm) x 270...
  • Página 27 3”(7.6 cm) x 12 (12’x12’) (366 x 366 cm) x 16 (12’x16’) (366 x 488 cm) ERECTING CONSTRUYENDO x 16 (12’x12’) (366 x 366 cm) x 20 (12’x20’) (366 x 610 cm) WALLS 2”(5 cm) x 24 (12’x24’) (366 x 732 cm) x 20 (10’x12’) (366 x 488 cm) LOS MUROS x 24 (10’x16’) (366 x 610 cm)
  • Página 28 3”(7.6 cm) x 21 (12’x12’) (366 x 366 cm) x 27 (12’x16’) (366 x 488 cm) ERECTING CONSTRUYENDO x 22 (12’x12’) (366 x 366 cm) x 33 (12’x20’) (366 x 610 cm) WALLS x 28 (12’x16’) (366 x 488 cm) x 39 (12’x24’) (366 x 732 cm) LOS MUROS 2”(5 cm)
  • Página 29 x 66 (12’x12’) (366x366cm) 3”(7.6 cm) x 78 (12’x16’) (366x488cm) DOUBLERS DOBLADORES x 90 (12’x20’) (366x610cm) x 102(12’x24’) (366x732cm) 12’ x 12’ (366 x 366 cm) 12’ x 16’ (366 x 488 cm) TOP VIEW TOP VIEW 1-5/8" (4 cm) 148”...
  • Página 30 1-1/2”(3.8 cm) TECHO ROOF x 12 x 40 Conjunto de vigas terminals x2 End Rafter Assembly x2 Flush Nivelado Red Ends Términos rojos Glue Pegamento UW x2 148" (376 cm) 1-1/2”(3.8 cm) 3”(7.6 cm) ROOF TECHO x 24 Middle Rafter Assembly Conjunto de vigas centrales (Ver las dimensiones abajo (See sizes below for quantity)
  • Página 31 3”(7.6 cm) x30 ROOF TECHO 2”(5 cm) x10 x 40 3”(7.6 cm) x10 Fijando las vigas y los bloques del sofito. Attaching Rafters and Soffit Blocks (Ver abajo para las dimensiones.) (See below for dimensions) 3” (7.6 cm) x 54 Repeat step on each rafter 24”...
  • Página 32 2”(5 cm) TECHO ROOF x 40 See Page 9 For Building Tip!!! ¡Ver la página 7 para un consejo!!! x160 12’x12’ (366 x 366 cm) REPEAT ROOF PANEL LAYOUT FOR BOTH SIDES OF ROOF x220 12’x16’ (366 x 488 cm) REPEAT ROOF PANEL LAYOUT FOR BOTH SIDES OF ROOF REPEAT ROOF PANEL LAYOUT FOR BOTH SIDES OF ROOF x280...
  • Página 33 1-1/2” (3.8 cm) TECHO ROOF x 92 x 40 Gable Panels Paneles del techo a dos agues DRY FIT PANELS AS SHOWN HERE BEFORE ASSEMBLING Los paneles montan según lo visto Groove Groove Groove Surco Surco Surco Compruebe la alineación del Dry fit assembly on front and back of building to determine surco en frente y la parte...
  • Página 34 2”(5 cm) 3/4”(1.9 cm) MOLDURA TRIM x 150 x 40 WJ x2 YB x4 WT x2 3 /8 " (.9 c m ) 12x12 (366x366cm) Shown x162 12x16 (366x488cm) 12x24 (366x732cm) WJ x2 WJ x2 WJ x2 WJ x2 WJ x2 WJ x2 WT x2 WT x2...
  • Página 35 1-5/8”(4.1 cm) DOOR PUERTA 3/8” (.9cm) 3/8” (.9cm) 7/16” (1.1cm) Parte Superior 7/16” (1.1cm) DOOR PUERTA Place a center mark for door location Ponga un señal en el centro para la puerta Cut out bottom plate at door opening Leave treated sill on concrete slab if desired Corte la placa inferior en la abertura de la puerta.
  • Página 36 3” (7.6 cm) x 6 DOOR PUERTA 1” (2.5 cm) 2” (5 cm) x 8 x 12 Inside Building Interior del edificio C x6 Attach with 3” (7.6 cm) Screws first, check doors to open properly and nail Fije con tornillos de 3" (7.6 cm) primero, compruebe que las puertas abren bien y clave.
  • Página 37 2”(5 cm) DOOR PUERTA x 20 M x 4 WGR x 2 WGL x 2 Diamond Traditional X Plain Contemporary Outer Diamond Double X Inner Diamond Lower Octagon Countryside Octagon 2”(5 cm) 1”(2.5 cm) DOOR PUERTA x 24 x 20...
  • Página 38 1”(2.5 cm) 2”(5 cm) DOOR PUERTA x 20 x 23 Inside View Visión Interior Exterior Trim Exterior Moldura 2”(2.5 cm) DOOR PUERTA x 12 UP x 2 Top View: Attaching Door Stiffiner Visión De arriba: Atadura del apoyo de la puerta Existing Door 2“...
  • Página 39 1”(2.5 cm) DOOR PUERTA CORCHETE x 14 Flush Nivelado HOOK AND EYE...
  • Página 40 DOOR HANDLE TIRADOR 1/2”(1.2cm) 1/2”(1.2cm) 5/8” (1.6cm) 1-3/4” (4.5cm) 35” (89cm)
  • Página 41: Pintura Y Masillado Tejas

    PAINT AND CAULK PINTURA Y MASILLADO TEJAS (Not Included) (No Incluidas) (No Incluidas) Use Acrylic Latex Caulk that is paintable. Caulk at all Use un masillado acrílico de latex que se puede pintar. Masille todas las junturas horizontales y verticales, entre la horizontal and vertical seams, between the Trim and moldura y los muros, y alrededor de la moldura de la Walls, and all around the Door Trim.
  • Página 42 SHINGLES (Not Included) x 40 Building Size Shingles Needed 1/2" 1" Dimensiones del edificio Tejas Necesarias 1" (1.3 cm) (2.5 cm) Sealing Strip (2.5 cm) Sellador 6 Bundles/bultos 12’ x 12’ (366 x 366 cm) 8 Bundles/bultos 12’ x 16’ (366 x 488 cm) 10 Bundles/bultos 12’...
  • Página 43: Nail Inspection Nail Inspection Inspección De Clavos

    SHINGLES TEJAS (Not Included) (No Incluidas) x 40 Ridge Cap Tapa de cumbrera Cut Shingles into 3 pieces Corte las tejas en tres partes 5-1/8" (13 cm) Apply pieces to ridge as shown Fije las piezas a la cumbrera como en el dibujo 5-7/8"...
  • Página 44: Garantía Limitada

    WARRANTY Marco Wood Products warrants the following: Limited Conditional Every product is warranted from defects in workmanship and manufacturing for one year. All hardware and metal components are warranted for two years. Warranty * Trim is warranted for 10 years. Waferboard siding and sheathing is warranted for two years.

Este manual también es adecuado para:

Premier serie

Tabla de contenido