A - SAFETY & MAINTENANCE INTRUCTIONS
Please read these instructions carefully. Basic operation is depicted on the back of the unit.
Make sure the black and red clips never come into contact (short-circuit).
Don't smoke or make sparks in the vicinity of a charging battery - Hydrogen from a battery on charge could
cause an explosion.
Always keep your Accupower charged. Leaving it flat may lead to irreversible damage.
Recharge after each use.
Never exceed 14.9V/4A when recharging with a charger other than the one supplied with the
DX.B1600
unit.
Failure to comply with these instructions will invalidate the warranty
B - SPECIFICATIONS
Voltage
Rated capacity (20 hr)
Peak current
Starting current
Charge rate
Charging voltage at 25°C
Copper cable cross-section
Cable length
Capacity indicator
Overvoltage protection
Automatic charger
Input
Output
Automatic trip at
Charging current
Weight
Length
Width
Height
DX.B1100
12V
12V
1100A
400A
5A/hr max
14.9V max
35 mm 2
650 mm
3 LEDs
Yes
Yes
230 V
12 V
14.8 V
1500mA
9.1 Kg
370 mm
110 mm
320 mm
DX.B1100
or
DX.B1600
12V
12V
1600A
700A
10A/hr max
14.9V max
35 mm 2
650 mm
3 LEDs
Yes
Yes
230 V
12 V
14.8 V
1500mA
9.3 Kg
400 mm
120 mm
350 mm

Publicidad

loading

Este manual también es adecuado para:

Accupower dx.b1600