Operation
AC/DC Current Measurements
WARNINGS:
Disconnect the test leads and temperature probe from
the meter before making current clamp measurements. Do not measure
current on conductors that are more than 600V above earth ground.
Observe all safety precautions when working on live conductors
1. Set the rotary function switch to the AC 400A or 40A or the
DC 400A or 40A position.
2. If the range is not known, select the higher range first, and then move to the
lower range if necessary.
3. When measuring DC current, press the REL button to zero out the display
before taking a reading. Keep the jaw closed when zeroing the meter.
4. Press the trigger to open the jaw. Clamp around a single conductor making
sure the jaws are fully closed before taking a measurement. For best results,
center the conductor inside the jaw.
5. Read the current on the LCD display.
600V
CAT
III
400A
Non-Contact
Voltage Detector
OFF
AUTO
POWER
OFF
Hz %
MODE
REL
NO
Incorrect
600V
CAT
III
400A
Non-Contact
Voltage Detector
OFF
AUTO
POWER
OFF
Hz %
MODE
REL
YES
Correct
7
Operation cont.
DC/AC Voltage Measurements
WARNING:
Observe all safety precautions
when working on live voltages.
1. Set the rotary function switch to
to the VAC/DC, Hz position.
2. Insert the black test lead into the
negative COM input jack and the
red test lead into the positive V
input jack.
3. Select AC or DC with
the
button.
4. Connect the test leads in parallel to the circuit under test.
5. Read the voltage on the LCD display.
Resistance Measurements
WARNING:
Never test resistance
on a live circuit.
1. Set the rotary function switch to the
2. Insert the black test lead into the
negative COM input jack and the
red test lead into the positive
input jack.
3. Press the
button until the
" " symbol appears on the display.
4. Touch the test probe tips across
the circuit or component under test. It is best to disconnect
one side of the device under test so the rest of the circuit
will not interfere with the resistance reading.
5. Read the resistance on the LCD display.
600V
CAT
III
400A
CAT
Non-Contact
III
Voltage Detector
Non-Contact
Voltage Detector
OFF
MODE
Hz %
OFF
AUTO
POWER
OFF
MODE
Hz %
REL
V
600V
CAT
III
400A
•))) CAP position.
CAT
III
Non-Contact
Non-Contact
Voltage Detector
Voltage Detector
OFF
MODE
Hz %
OFF
AUTO
POWER
OFF
MODE
Hz %
REL
Ω
8
600V
400A
AUTO
POWER
OFF
REL
600V
400A
AUTO
POWER
OFF
REL