Adapter Kit for PanelView 1400e Touch Terminal Cutout
Package Contents
The cutout adapter kit includes:
• cutout adapter plate with gasket and ball bearing spacers
• 18 #10-32 nuts with flat washers for 1500 keypad
• 12 #10-32 nuts with flat washers for 1500 touch
Tools Required
These tools are required for installation:
• socket driver with 3/8 inch socket
• slot or Phillips screwdriver
• torque wrench capable of 10 lb-in
Disconnect Power to the Terminal
1. Disconnect power at the source and remove the power cord from the
PanelView terminal.
2. Disconnect all communication cables from the terminal.
ATTENTION
Remove the Existing Terminal
1. Remove the nuts and washers that secure the terminal in the panel and save
them for the adapter plate installation.
2. Slide the existing terminal out from panel.
Publication 2711P-IN011C-MU-P - March 2007
Make sure the power cord of the PanelView terminal is disconnected and that
all cables have been disconnected from the terminal.