1/4" and 3/8" L12 Atomist Lubricators
Fill Plug
O-ring
Flapper
Polycarbonate
Bowl
(See Warning)
(Do Not Scratch
Internal Surfaces)
Bowl Guard
Retaining Collar
(Hand Tighten
Plus 1/4 Turn)
Lightly grease with provided lubricant. (Silicone free)
Inspect for nicks, scratches, and surface imperfections.
If present, reduced service life is probable and future
replacement should be planned.
Clean with lint-free cloth.
3. Oil delivery adjustment — To adjust oil delivery, turn
adjustment knob on top of the lubricator.
Leaner — Clockwise
Richer — Counterclockwise
By counting the number of drops per minute in the sight
dome, you can adjust to your requirements.
Atomist lubricator — Approximately 3% of the droplets visible
in the sight dome go downstream; adjust drip rate accordingly.
Consult oil delivery conversion chart.
Generally, one drop per minute downstream for every
10 - 15 SCFM flow is satisfactory.
25 drops per minute equals one (1) ounce per hour - volume
of oil passing through the sight dome.
Sight
Dome
Seal
Filter Body
(Internal
Surfaces)
O-ring
Seal
Siphon Tube
O-ring
Metal Bowl
(Sight Glass
Shown)
Fill Button Assembly
Torque:
2.8 to 3.4Nm
(35 to 30 in. lbs.)
Manual
Body Force
Drain
Fill Adapter
(Hand Tight)
O-ring
Body Force Fill Adapter Kit
LRP-96-302
O-ring
Fill Button Assembly
Torque:
2.8 to 3.4Nm
(35 to 30 in. lbs.)
Bowl Force Fill Adapter Kit
LRP-96-304
NOTE: This is a constant density type lubricator which delivers a constant
ratio of oil to air flow. Therefore, if air flow increases or decreases, oil
delivery will be adjusted proportionately. ONLY IF A DIFFERENT RATIO
IS DESIRED SHOULD YOUR ADJUSTMENT KNOB SETTING BE
CHANGED AFTER YOUR INITIAL SETTING.
Oil Delivery Conversion
3% of Drip Rate to Downstream
7
6
5
4
3
2
1
33
67
Dome Drip Rate DPM
4. To replace fill plug, drip control, and service lubricator:
A. Turn off air supply and depressurize the unit.
B. Refer to pictorial for servicing and torque values.
C. Turn on air supply and check lubricator for leakage. If
leakage occurs, DO NOT OPERATE — conduct repairs
again.
Service Kits Available
Description
Adjustment Knob
Bowl Guard Kit
Drip Control (Polycarbonate)
and Fill Plug Kit
Lubricator Repair Kit
Body Force Fill Adaptor Kit
Sight Dome Kit
Sight Gauge Kit
Metal Bowl Kits
Manual Drain
Piston Drain
Sight Gauge and
Manual Drain
Sight Gauge and
Force Fill Adapter
Polycarbonate Bowl Kits
Manual Drain
Bowl Force Fill Adapter Kit
Drain Kits
Manual Drain
83-955-000
100
167
200
133
L12
1/4" and 3/8"
LRP-96-300
GRP-96-345
LRP-96-307
LRP-96-309
LRP-96-302
LRP-96-301
GRP-96-346
GRP-96-348
GRP-96-353
GRP-96-349
LRP-96-305
GRP-96-347
LRP-96-304
GRP-96-340
233