4.2.1
Turn on
Press the ON/ZERO key, it starts to display version number, the battery voltage level and
9,8,7···1,0 for self-checking, then the zero led on. Now the scale is ready to work
4.2.2
Turn off
Long- press OFF key.
4.2.3
Auto-off
After 10 minutes in zeroing, auto-off.
4.2.4
Low voltage auto-off
When the voltage lower than 5.6V, it will power-off.
4.3. ZERO
When the scale without tare operation and the weight is ≤4%F.S., press the ON/ZERO key,
the display shows 0 and the zero led on.
4.4. WEIGHING
Put commodities on the pan.
4.5. TARE
Press the TARE key, it displays 0, the zero led off and the tare led on. Remove the weight
and it will display the negative value and the zero led on, press the TARE key again, it
displays 0 and the tare led off.
4.6. POWER SAVING
Zero after 40 seconds, it will show only 0 for saving power, and will wake up if there is any
weight put on.
4.7. BATTERY INDICATION
Battery full – voltage > 6.3V
Battery voltage between 6V and 6.3V
Battery low – voltage <6V
4.8. CHARGE BATTERY
Power supplied by an internal rechargeable lead acid battery (6V/4Ah). When it shows
-bAtLo-, please turn off and charge it immediately. The time of full charging is 12 hours.
4.9. FUNCTIONS AND PARAMETERS SET
Press SET/0-9 key 3 seconds to set. Now show rAngE. Press SET/0-9 to shift between
functions of unitS/A-oFF/Filt/ZEro/BuZZEr/d/d-dP.
4. 9.1 rAngE – Checkweigh
When it displays rAngE, press TARE. Now the under/- led on. Press SET/0-9 to increase
the digit and press TARE to confirm and move to next digit. Once you finish the
under/- limitation set, when you press TARE, the over/+ led turns on, then push SET/0-9
and TARE to change and confirm the upper limitation and exit.
when weight ≥ high limit, over/+ led on.
when low limit < weight < upper limit, OK/Accept led on.
when weight ≤ low limit, under/- led on.
Caution:
WSS/SUPER USER MANUAL
1. when the display is not stable, this function would not active
2. when the low limitation value set > upper limitation, it will display oFF
3