Install the Fixture
Note: Multiple fixtures may be interconnected at any
distance apart in accordance with NEC specifications.
1A
1
Place and level the unit in the desired position.
Mark the two points under the cabinet through the
2
mounting holes.
1B
MOUNTING SCREW
3
Secure the fixture with an appropriate sized mounting
screws.
1C
4
5
1D
6
MOUNTING SCREW
7
8
9
10
2
KNOCKOUT
COVER
COVER SCREW
Unscrew the cover screw and swing open the cover.
Determine the desired location of the conduit
connection and remove one of the many knockouts
locations provided.
Install the conduit adapter to the determined knockout
location and feed the flexible conduit and the power
lines into the fixture. Secure it by tightening down the
screw on the conduit adapter.
Connect the white driver wire to the neutral power line
with a wire nut.
Connect the black driver wire to the hot power line with
a wire nut.
Connect the fixture to a suitable ground in accordance
with local electrical code.
Properly place the wires and wire nut connections into
the fixture, replace the cover, and secure it with the
screw (reversal of step 1C).
FLEXIBLE CONDUIT
7
8
9
FLEXIBLE CONDUIT ADAPTER