SAVE THESE INSTRUCTIONS
Operations Guide for
GPI Scaled Pulse Module
Local Model
TABLE OF CONTENTS
English ........................................................................1
Spanish..................................................................... 11
E N G L I S H
GENERAL INFORMATION
This manual will assist you in operating and maintain-
ing the GPI electronics supplied with your GPI meter or
as an accessory unit on both local and remote models.
The GPI Electronics can be used in indoor or outdoor
applications where occasional exposure to moisture is
common.
Display information in this manual supersedes display information provided with your meter.
04/12
SC510
www.gpimeters.net
1-888-996-3837
Remote Model
The Scaled Pulse Module can be used on all GPI
models, including the Precision G series, IM or the
Industrial Grade G2 series, the Commercial Grade A1
series and the Positive Displacement GM series oval
gear meters.
Product differences in this manual are identified by either
Local or Remote as necessary.
The GPI Scaled Pulse Module is a switch-programmable
multi-stage counter/divider with multiple inputs. Its
function is to provide a pulse output for each number of
input pulses. Input pulses are assumed to come from a
frequency-output flowmeter mechanism.
GPI flowmeters have a "K-factor" which is the pulse
output per unit volume measured stated as "Pulses Per
Gallon" (PPG). Other flowmeters also have a "K-factor"
as determined by their manufacturer. Verify the "K-factor"
unit of measurement before programming this equip-
ment. In a flowrate-measuring system, it's desirable
to have an output signal that has been converted to
a standard unit of measure, such as gallons. Such an
output can then be used to drive "off-the-shelf" display
units and/or relays.
5252 East 36th Street North
Wichita, KS USA 67220-3205
TEL: 316-686-7361
FAX: 316-686-6746
SC500
Rev. - 920888-01
1

Publicidad

Tabla de contenido
loading

Resumen de contenidos para GPI SC510

  • Página 1 GPI Scaled Pulse Module Local Model Remote Model SC510 SC500 The Scaled Pulse Module can be used on all GPI TABLE OF CONTENTS models, including the Precision G series, IM or the Industrial Grade G2 series, the Commercial Grade A1 English ................1 series and the Positive Displacement GM series oval Spanish..............
  • Página 2: Safety Instructions

    Industrial Grade G2 Series: ules, perform this conversion by counting and accumu- • Local – The SC510 Scaled Pulse Module requires lating input pulses until the count reaches the known the GPI 510 Conversion Kit (Part #11344001) for K-factor. It then generates an output pulse. At that time local mounting to the G2 Series meter.
  • Página 3: Connecting The Equipment

    Connecting the Equipment: WIRING • Remove the faceplate by removing the four corner This manual refers to various models of GPI flowmeters. screws. Determine what type of input the electronics will receive • Attach wiring from your equipment according to the and what type of output, if any, you require.
  • Página 4 High Level, High Frequency input described above. NOTE: No additional components are usually required, since the GPI circuit contains a built-in “pull up” Note: Pull-up resistor only required if not supplied by receiving equipment. resistor at this input.
  • Página 5: Power Supply

    OPERATION OUTPUT The GPI Scaled-Pulse circuit has a single output. It is a When installing the GPI Scaled Pulse Module, make true open-collector type, referenced to any of the COM sure that all electrical connections are tight and secure. terminals. This output is rated for a maximum sink cur-...
  • Página 6: Troubleshooting

    If the meter’s K-factor is less than 1000.0 PPG, you must 645 PPG x 0.1 = 1/10th Gallon, set 64.5 set the left-most switches to “0”. Example: Meter K-factor is 75 PPG (10 Pulses Out = 1 Gallon) 645 PPG x 10.0 - 10 Gallons, set 6450 645 PPG x 1.0 = Gallon 645 PPG x 0.1 = 1/10th Gallon 64.5 645 PPG x 10.0 - 10 Gallons...
  • Página 7: Dimension Drawings

    DIMENSION DRAWINGS...
  • Página 8 ILLUSTRATED PARTS DRAWING - SC500 Item Part No. Description Req’d. 120509-01 Adapter Kit ........... 1 120058-01 Bracket ............1 12052001 Blank Coverplate Kit ........1 12052101 Circuit Assembly Kit ........1 125066-20 Cable, 20 ft..........1 901002-82 O-Ring ............1 901002-87 Seal .............
  • Página 9 ILLUSTRATED PARTS DRAWING - SC510 Item Part No. Description Req’d. 120059-01 Blank Coverplate Kit ........1 12052101 Circuit Assembly Kit ........1 12051701 Enclosure Kit ..........1 125066-20 Cable, 20 ft..........1 901002-82 O-Ring ............1 901002-87 Seal ............. 2 902005-9 Strain Relief ..........
  • Página 10 Mechanical Connections: be possible to diagnose the trouble and find a solution Unit is mounted directly to flowmeter body. with a telephone call. GPI can also inform you of any special requirements you will need to follow for shipping. Electrical Connections:...
  • Página 11: Información General

    Este manual le ayudará en la operación y manten- imiento de la electrónica de GPI que se suministra con NOTA: Esta unidad es alimentada por corriente conti- su medidor de GPI, o como una unidad de accesorio nua, lo que requiere una fuente de alimentación de...
  • Página 12: Pautas Para Cables

    Este manual se refiere a distintos modelos de medi- se conecta mediante un cable de salida como se dores de flujo de GPI. Determinar qué tipo de entrada muestra en el Diagrama de cableado. va a recibir la electrónica y qué tipo de salida, si los hubiere, que usted requiere.
  • Página 13: Fuente De Alimentación

    NOTA: Ninguno de los componentes adicionales se re- to errático. quieren por lo general, ya que el circuito GPI con- tiene un “contenedor” existente de resistencia en esta entrada. MEDIO AMBIENTE Todos los componentes electrónicos en el el módulo...
  • Página 14: Funcionamiento

    FUNCIONAMIENTO decimal, se debe redondear el número para que usted pueda ajustar los interruptores con una sola posición Al instalar el módulo de GPI de impulso escalado, decimal. asegúrese de que todas las conexiones eléctricas es- tén apretadas y seguras.
  • Página 15: Solución De Problemas

    SC500 - Dos puertos de alivio de tensión 2. La frecuencia se encuentra por encima de 1500 Hz. Proporcione una frecuencia más baja. SC510 - Un puerto de alivio de tensión: un tapón roscado 3. Fallo electrónico. Póngase en contacto con la fábrica.
  • Página 16 To make a claim against this warranty, contact the GPI Customer Service Department at 316-686-7361 or 888-996-3837. Or by mail at: Great Plains Industries, Inc.

Este manual también es adecuado para:

Sc500

Tabla de contenido