Pfister Pasadena 8P8 Serie Manual Del Usuario página 4

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

12
12A
CLOSED
12 VALVE FUNCTION
By rotating the Lever Handle (12A) slightly counterclockwise, the valve will be
fully activated to the "COLD" position. The water temperature can be increased
by continuing to rotate the Lever Handle (12A) in a counterclockwise direction.
13
UP
For
Shower
13A
13 TUB SPOUT FUNCTION
When the valve is turned on, water normaly flows through the Tub Spout (13A).
To activate the shower, turn valve on and pull the Knob (13B) up. Hold on until
water flows continiously from the shower arm.
14
14C
14B
14A
14 FINAL FLUSHING
For final flushing, turn valve on and allow water to run through the Tub Spout
(14A) for several minutes. Pull Spout Knob (14B) up to allow water to run through
Shower Arm (14C). Allow water to run for several minutes untill all foreign mater
clears the line.
FULL HOT
OPEN
FULL COLD
13B
ENGLISH
15
15A
15B
15 SHOWER HEAD FUNCTION
To adjust spray, turn Outer Shell (15A) using Switch (15B) to a desired spray
pattern.
16
16B
16A
16 SHOWER HEAD INSTALLATION
Thread Shower Head (16A) onto Shower Arm (16B).
Make sure Shower Head (16A) is securely tightened to Shower Arm (16B).
4
15A
15B

Publicidad

Tabla de contenido
loading

Tabla de contenido