Descargar Imprimir esta página

Orbis DECO ASTRO Instrucciones De Empleo página 2

Publicidad

Idiomas disponibles

Idiomas disponibles

INSTRUCTION FOR USE
Menu access key.
Validation of flashing data
INSTALLATION
An independent electronic device for mounting inside a universal (60 x 40) flush-
mounting box. To be connected as in the following diagram:
OPERATION
The DECO ASTRO is a timer switch for controlling lighting loads in function of
sunrise and sunset, which will depend on the geographic location where the
apparatus is installed. The geographic location is established by selecting the
closest city to your location from a list of the largest cities in your country.
The apparatus has twenty programs that can be configured astronomically or with
fixed times.
Programming is based on menus and submenus with the data to be programmed
displayed flashing.
The following information is displayed on the main screen:
 Day of the week.
 Complete time and date.
 Schedule with the pending actions for the current day (in PROGRAMMED
menu).
 Operating state On / Off.
 Hand symbol (if manual operation is activated).
 Sunrise and sunset times (the display will alternate between the two times).
The SUN symbol is displayed with sunrise time and a MOON symbol with
the sunset time.
KEY FUNCTIONS
Key ✓:
Accesses the various menus. The flashing data is valid.
Key ▲:
Move up the menu. It increments the flashing data. If it is held pressed,
the increment speed is five units per second. The main screen is
manually switched between the channel activation status (On / Off).
Key ▼:
Moves down the menu. It decrements the flashing data. If it is held
pressed, the decrement speed is five units per second. The main
screen is manually switched between the channel activation state (On /
Off).
Key C:
Go back to the previous option. The main screen switches between
these two states:
 PERMANENT: It does not execute programs. It remains in the
activation state that was set manually.
 PROGRAMMED: The equipment operates normally and displays the
schedule assigned to the current day.
TIME ZONE SELECTION (ZONE menu)
The closest geographic location is selected from a list of cities. The astronomic
switch will calculate sunrise and sunset times for each day of the year from the
geographic position.
Astronomic correction
When the geographic position is selected, corrections can be made to the sunrise
and sunset times to take into account topographic variations (for example,
shadows caused by buildings etc).
OPERATIONS PROGRAMMING (PROGRAM menu)
This is the menu used to configure the 20 programs held in the equipment. The
▲/▼ keys are used to move through and display each menu. If you wish to access
ASTRONOMIC TIMER SWITCH
DECO ASTRO
Key for moving back to the
previous option. Commutes
the main screen between
Permanent and Programmed
Function
selection keys
Metal frame
Trim frame
Connection is via rear terminals with holes
for conductors with maximum 2.5 mm
section.
Installation shall be carried out by an
officially authorised installer. It must not be
installed close to inductive loads (motors
and transformers etc). It is recommended
that it has a separated power supply line,
fitted with a mains filter if required).
Before connection and complete installation
of the device, it must be verified that mains
power has been switched off.
a specific program, simply press the "3" key. There are several options within the
desired program:
 EDIT: Create or modify the program configuration. It will request the type of
action to perform (On / Off). The next screen is used to enter time when the
action is to be performed:
o FIXED:
Perform the action at a selected fixed time.
o SUNRISE: Perform the action at sunrise. A correction can be made to the
sunrise time.
o SUNSET: Perform the action at sunset. A correction can be made to the
sunset time.
 COPY:
Copy the selected programming.
 PASTE:
Paste the previously copied programming into another program.
 DELETE: Delete the programming for the selected program.
CLOCK MENU
Establish the equipment time. The variables to be configured are (in this order):
year, month, day, day of the week, hour, minute. When the minutes are confirmed,
it automatically changes to the MAIN MENU and the date and time are saved.
LANGUAGE MENU
Establish the equipment, English, Portuguese or Spanish can be selected.
ADJUSTMENT MENU: This provides access to the more complex equipment
functions. These are the following:
 SEASON submenu: This allows season change to be configured, selecting
from:
o AUTOMATIC:
o MANUAL:
o DEACTIVATED: Does not perform any seasonal time changes.
 STATE submenu: This enables the equipment to left without any programs
during a certain period of time without having to delete them. The options are:
o OFF:
The equipment is in the OFF mode (everything works except the
programs). The output relay remains OFF.
o ACTIVE:
The equipment permits execution of any program.
o NUM DAYS: Timer programming will not be executed during a preset number
of days (for example: during holidays).
 CONTRAST submenu: For the selection of minimum, low, medium, high or
2
maximum contrast. When a key is pressed, contrast is automatically set to high
for three seconds. If, after this time passes, no other key has been pressed, the
contrast level will return to where it had been previously set.
 VERSION submenu: This `provides a fast way of displaying the firmware
version. This will be the type: V1.00.
POWER SUPPLY RESET AND SWITCH OFF
With any power applied, the date and time will be maintained during 24 hours and
the programs and parameters will be held in memory. Reset is performed by
pressing all four keys simultaneously.
TECHN ICAL SPECIFICATIONS
- Power supply voltage:
- Own consumption:
- Breaking power:
- recommended maximum loads:
Incandescent lamps:
Fluorescent lamps
Low voltage halogen lamps
Halogens (230 V)
Low-consumption lamps
Downlights
Leds
- Operation type:
- Operation precision:
- Power reserve:
- Protection type:
- Protection class:
- Operating temperature:
- Directives:
- Marking:
DIMENSIONS
05.2017
Changing to summertime at 02:00 on the last Sunday in
March and wintertime at 03:00 on the last Sunday in
October.
This allows specific dates and time to be established for
both changes.
230 Vac 50 Hz ± 10%
Maximum 3.4 VA Inductive (1.3 W).
8 (2) A / 250 Vac
2000 W
1000 W
1000 VA
2000 W
600 W
400 W
90 W
1B, 1T, 1U, 1S (for manual operations)
± 1 s/24 h at 23 ºC (quartz crystal)
24 h using a supercapacitor.
IP 20 according to EN 60529
II
according
assembled
0 ºC to +40 ºC
2002/95/EC (RoHS), 73/23/CEE y
93/68/CEE (electrical safety),
89/336/CEE y 92/31/CEE (CEM)
CE
93
60
ORBIS TECNOLOGIA ELECTRICA, S.A.
Lérida, 61
Telephone: +34 91 5672277;
E-mail: info@ orbis.es
http://www.orbis.es
to
EN
60335
fully
45.5
31
A016.35.55115
E-28020 MADRID
Fax: +34 91 5714006

Publicidad