QUICK PROGRAMMING GUIDE 905-ZA PROCESSOR
Start/on
Main menu
Transcodifi cador 912 QPSK - COFDM
Select series
NIT Table
Select series
905-ZA Programmable fi lter
912-TP Transmodulator QPSK-PAL
905-ZA Programmable fi lter
Confi gure module
Select the button
102, press T (transmit) to activate the programming mode. Press the PRG pushbutton of the
Model
ZA-431 Processor
Program by
Channel
Channel
Frequency
Channel table
BG CCIR
Channel
21
Frequency
471.25
Mode
Digital
Bandwidth
8
Off set
0
Adjust level
+0.5
Automatic level adjust
Select the button
and, while pointing at the PA-320 amplifi er or at the IP-
Programming On/Off
MHz
MHz
MHz
dB
and, while pointing at the PA-320 amplifi er or at the IP-102,
Programming On/Off
press T to deactivate the programming mode.
Press the Power On key of the PS-011 to start up the
system.
Choose Select Series to select the programming series.
OK
Select the series: 905-ZA Programmable fi lter.
OK
To commence programming the module, select Confi gure
OK
module.
fi rst ZA.
Select the 905-ZA processor to be programmed: ZA-431
OK+
+OK
or ZA-331.
Select the programming mode of the output of the
OK+
+OK
module: channel or frequency.
Select the standard for the output channel.
OK+
+OK
Keypad + T
If you are programming the output by channel, enter the
or
fi rst and last channels. After confi rming with OK, press
OK+
+OK+T
T to transmit.
If you are programming the output by frequency, enter
Keypad + T
the frequency using the numeric keypad. Then press T
to transmit.
Select Analogue mode for analogue channels or Digital
OK+
+OK+T
mode for digital channels. Then press T to transmit.
Select the bandwidth of the output channel: 7 or 8 MHz.
Keypad + T
or
You can do this by using either the numeric keypad or the
OK+
+OK+T
pulldown menu. Then press T to transmit.
Select the input/output offset for the digital channel. This
OK+
+OK+T
option is not available if it is an analogue channel. Then
press T to transmit.
Select the output level from the list. Then press T to
OK+
+OK+T
transmit.
Press the PRG pushbutton of the next ZA to be programmed and return to selecting
the model, using the cursor keys to repeat the process.
When all the modules have been programmed, move
T
over the button for setting the levels automatically and
press T to transmit. No with IP-102.
ENG