JENN-AIR JGCP430ADP Instrucciones De Instalación página 9

Ocultar thumbs Ver también para JGCP430ADP:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

To Convert Appliance For Use With Natural Gas
WARNING
Electrical power and gas must be turned
off prior to conversion.
If this appliance has been converted for use with LP gas,
each of the following modifications must be performed to
convert the unit back to natural gas.
A. Replace all orifice spuds
Perform Steps 1 through 3 on page 6.
For Step 4: Locate the colored brass natural gas
orifice spuds that were originally installed in this
appliance before its conversion for use with LP gas.
Observe the color of each of the spuds and note the
correct burner location for each spud as shown on
page 10 figures 17, 18 or 19.
Complete Steps 5, 6, and 7 on page 6 to complete
the installation of natural gas main spuds in their
correct locations.
Save the orifices removed from the appliance for
future use. They will be needed if this appliance is
again converted for use with LP gas.
B. Invert cap in appliance pressure
regulator.
(See figure 13 or 14.)
With the appliance installed the appliance regulator
should be located as shown in figure 8. Identify the
type of appliance regulator and follow the instructions
in the appropriate illustration.
C. Adjust low flame as instructed on page 8
item C.
After Steps A, B and C have been completed, check
the appearance of each burner's flame at the Hi and
Lo settings against figure 16. If the flames appear too
large or too small, make sure all steps were
completed correctly.
9

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Jgcp636adpJgcp648adp

Tabla de contenido