Oil Preheating Program
The machine has a preprogrammed function that heats up and conditions the oil in the pump to ensure
maximum performance and durability. It heats up the oil and separates impurities from the oil, prolonging
the life of the pump. It is recommended to run this procedure if the unit has not been used for a while
(24-plus hours). The procedure takes 15 minutes to run.
1. Plug into outlet.
2. Press ON (I)/OFF ( ) button. The unit will be in standby mode and display will show "ooo."
3. Press and hold OIL PREHEAT FUNCTION
"15."
4. Close lid.
5. Unit will run 15 consecutive 1-minute cycles. Display will count down number of cycles until cycles are
completed. When completed, lid will open and display will return to "ooo," indicating it is ready for use.
Operation
1. Plug into outlet.
2. Press ON (I)/OFF ( ) button to turn on unit.
3. If unit has not been used in the last 24 hours, run preheating program (see above).
4. Place food in a vacuum-sealing pouch. Place pouch into chamber with open end positioned over
sealing bar.
NOTES:
•
If the contents are small, use insert plates to minimize space in chamber. This will reduce cycle time.
•
The pouch should not extend outside chamber and should be placed over sealing bar, free of folds.
•
Multiple pouches can be placed over sealing bar if sealing bar is longer than pouch openings.
Do not overlap pouches.
5. Press PROGRAM SELECT
6. Close lid. Do not use lid retainer. Cycle begins automatically.
7. Lid opens automatically when cycle is complete.
8. Remove contents and wait 10 seconds before beginning another cycle.
NOTES:
•
To stop vacuum process and move to next step, press +/STOP VAC
•
To stop and cancel cycle, Press –/STOP
6
button until program display shows "C," and display shows
button until desired program is displayed.
button.
button.