Usage
For use with 1, 2 or 3-Hour-Rated Floor-Ceiling and Roof-Ceiling Designs.
UL/ cUL Listed for use in the following Floor Ceiling and Roof Ceiling Assemblies: L521, L528, L546, L558, L562,
L574, L576, L581, L583, L585, P522, P533, P538, P545, and P547 when installed per the following instructions.
Flat Ceiling / Horizontal Mount Only.
For use with the following ventilation fan models:
Broan AE110-B, AE50110DC, AER110KC, AE110K, AE80K, A80-B, A80HD-B, AE50-B, AE80-B, AE80B-B, A110-B,
AER50-B, AER80-B, AER110-B, AR80X-B, AR110-B, AE50110DCS, AE110S-B, AE80S-B, AE80BS , AE50110DCL,
AE80BL-C, AE80L-C, AE110L-C, AER110L-C, AE80LK, AE110LK, AE50110DCSL, AE80SL-C, AE110SL-C
NuTone AEN110-B, AN80C-B, AEN50-B, AEN80-B, AEN80B-B, AN110-B, AERN50110DCKC, AERN110K,
AERN80K, AERN80KC, AEN80BS , AEN80BL-C, AEN80L-C, AEN110L-C, AERN80LK, AERN110DCSL
PennBarry ZQ75
Remove Blower & Wiring Panel
The following steps are best performed on a work surface before
fan installation. Protect counter tops by placing corrugated sheet
under the fan.
1. Remove blower and all packing material from fan housing.
2. Remove wiring
panel from fan
housing.
Install Metal Duct Connector
CAUTION
• Do not use plastic duct connector
supplied with fan. Replace this part with
metal duct connector supplied with
radiation damper.
TABS
3. Discard plastic duct connector supplied with fan. It must not
be used.
4. Install metal duct connector supplied with radiation damper.
a. Push duct connector through opening from inside of
housing.
b. Engage tabs and secure with #8-18 hex head screw from
parts bag.