Telcoma Automations ZEN 100E Manual Del Usuario página 59

Automatismo para puertas seccionales y basculantes
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 34
GB
DOOR POSITIONING MANOEUVRE
This procedure enables manoeuvring as required of the door connected to the gearmotor, to prepare the system for
programming and to check gearmotor connections.
During this operation, the pushbuttons work in "hold-to-run" mode and safety devices are ignored.
Procedure:
1) Keep the PROG key pressed. Use a screwdriver to short the jump Reset (detail 17 of fig. 14).
2) Keep the PROG key pressed.
3) After three seconds led LD1 turns on.
4) Release the PROG key.
5) Activate the manual movement function by pressing PROG again
6) The led LD1 changes from a steady light to flashing. Procedure activated.
7) Press S/S to open the automation.
8) Press the PROG key to close.
9) To return to normal operating mode, reset the control unit (short the connector, detail 17 of fig.14)
6
Exit
MANUAL DOOR RELEASE
To open the door, also without power, proceed as follows:
- for safety reasons, disconnect the 230V power supply
- move to below the guide in the vicinity of the release tie-rod
- pull first downwards and then towards the gearmotor (see figure 16).
The device blocks automatically when the door is closed again.
Fig. 16
59

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Zen 60eZen 100Zen 60

Tabla de contenido