Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Device Operation

Note: A preliminary test should be
conducted before proceeding to
a full treatment. (See Preliminary
test section above).
See treatment areas, treatment
time and treatments schedule in
the Recommended treatment
section below.
1.
Prepare the treatment area
as detailed in "preparing the
treatment area" section
above.
Apply an even layer of
2.
the Base Gel included in your
kit, on the area that is
intended for treatment.
3.
Set the RF energy level to
the level you found most
comfortable when you
carried out the preliminary
test. Press the RF energy
level selection button
repeatedly until you reach
the desired level: 1, 2, or 3.
4.
Place the device on the
intended treatment area,
ensuring full contact of the
electrodes with your skin
throughout the entire
treatment. If the device is not
properly placed, the RF energy
and massage will not be
delivered. When the device is
working, you will feel and hear
a gentle vibration, and the
indicator will be lit up in green.
5. Move the device over the
treatment area in slow circular
motions, while maintaining
constant, firm contact with
the skin.
6.
If you do not feel a sensation
of warmth after approximately
30 seconds, try moving the
Sensifirm over a smaller
treatment area, and/or
increasing the RF energy.
At the end of each treatment
7.
pressing on the energy
selection button. An orange
indicator light will light up
while the device is shutting
down. After the light has
from the electrical outlet.
8.
After completing the
remaining Base Gel from the
treated area.
Clean the device with a soft
9.
damp cloth or paper towel,
according to the cleaning
instructions in the Cleaning
section below.
13

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido