ASPIRE
self-priming pump
for swimming pool
MONOPHASIC
1
2
3
4
5
6
CAUSES
•
•
Air entering the suction pipe
•
Filter cap badly sealed
•
•
Inverted motor turning
•
•
•
Wrong voltage
•
Pre-filter blocked
•
Load loss in the installation
•
Pump incorrectly secured
•
Motor blocked
Increased temperature in the terminal
•
box due to electric arc
•
The thermal protection trips
•
Incorrect terminal box connections
Troubleshooting
1. The pump is not primed
2. The pump releases only a small flow of water
3. The pump makes a noise
4. The pump will not start
5. The motor is making a noise but will not start
6. The motor is stopped
SOLUTIONS
Check the condition of connections and
seals on the suction pipe
Clean the filter cap and check the
condition of the rubber seal
Invert 2 power phases
Check the voltage on the characteristics
plate and that of the mains
Clean the filter
Prevent parts from causing load loss
wherever possible
Secure the pump correctly
Remove the motor and contact the
technical service
Check the terminal box connections
Connect the cables correctly to the
terminal boxes
Tighten the cable correctly to the
terminal / Adapt the size of the cable
connection to the terminal box