INSTALLER MATERIALS CHECKLIST
The following materials checklist is provided to assist in installation preparations. Installers may find it helpful to
verify that all materials are available.
Circuit breaker, check product labeling for breaker requirements.
Conduit and fittings, 3/4 inch for AC power.
Punch for distribution panel, 3/4 inch conduit (26 mm).
Wire strippers
GENERAL INSTRUCTIONS
The Surge Protective Device (SPD) mounts directly to the service panel to be protected. Whenever possible, use
the first circuit in the service panel. Wire lengths of 24" (60 cm) or less are desirable. The shortest possible wire
length enhances the suppressor's performance by allowing less let-through voltage into the protected equipment.
INSTALLATION AND CONNECTION OF SUPPRESSOR
Install the SPD breaker. NOTE: Not all products require a separate SPD breaker. Check product labeling
for requirements
Find and mark a suitable location (3/4 knockout preferred) for mounting the suppressor to the distribution
panel.
320-0221 REV D
AC2100/AC21SM/AC4100 SERIES
INSTALLATION INSTRUCTIONS
Location of Suppressor
Shown with SPD breaker
Page 1 of 4

Publicidad

loading

Resumen de contenidos para Raycap AC2100 Serie

  • Página 1 AC2100/AC21SM/AC4100 SERIES INSTALLATION INSTRUCTIONS INSTALLER MATERIALS CHECKLIST The following materials checklist is provided to assist in installation preparations. Installers may find it helpful to verify that all materials are available. Circuit breaker, check product labeling for breaker requirements.  Conduit and fittings, 3/4 inch for AC power. ...
  • Página 2 Note that normally open and normally closed are in the energized condition. Check ALL wiring. Incorrect wiring may result in damage. For conditions other that those described above, please contact an Raycap Account Representative at (208) 777-1166, (800) 890-2569, or Fax (208) 777-4466 or www.raycapinc.com...
  • Página 3 SERIES AC2100/AC21SM/AC4100 INSTRUCCIONES DE INSTALACIÓN LISTA DE MATERIALES DE INSTALACIÓN La siguiente lista facilita las preparaciones para la instalación. Verificar de antemano que todos los materiales estén disponibles puede ayudar al instalador. Interruptor, revise la etiqueta del producto para ver los requisitos del interruptor. ...
  • Página 4 Revise TODOS los cables. Pueden producirse daños si se cablea incorrectamente. Para otras circunstancias no descritas en este documento, por favor llame a un Representante de Raycap al (208) 777-1166, (800) 890-2569, por Fax (208) 777-4466, o a través de www.raycapinc.com...

Este manual también es adecuado para:

Ac21sm serieAc4100 serie