Installation
1.
Attach HDMI cables from video source to Transmitter and from
Receiver(s) to display(s).
2.
Attach Ethernet cables connecting between Transmitter and
Receiver(s).
3.
Connect and power on Transmitter and Receiver(s). Do not switch
on displays until resolution settings made.
4.
Define resolution of monitor(s) attached to Receiver
Select desired resolution from one of the option from table
below. Adjust "EDID DIP" switch, refer to table below. "0"
represents switch down. "1" represents switch up.
After DIP Switch set, press "SET" button to register setting.
NOTE: Receiver factory default setting is Bypass mode. All
monitors receive the same resolution setting as Transmitter setting.
(Go to Step 5 for Transmitter EDID setting).
NOTE: Transmitter and Receiver at factory default- all attaching
monitors at both Transmitter and Receiver receive 1080p 60Hz
video.
NOTE: Receiver sets Bypass mode, Transmitter sets Read
LOCAL OUTPUT EDID- Transmitter automatically reads EDID
from attached monitor and feeds the same setting to all monitors
attached to Receiver. When no local monitor directly connected to
Transmitter, EDID will be undetectable and may result display
error.