1. Connect the black probe to terminal COM and the red probe to terminal
2. Set the function switch to position
3. Connect the test plungers to the circuit and read the value displayed on screen once
it has stabilised.
1. Connect the black probe to terminal COM and the red probe to terminal
2. Set the function switch to position
3. Connect the test plungers to the circuit and read the value displayed on screen once
it has stabilised.
1. Connect the black probe to terminal COM and the red probe to terminal
2. Set the function switch to position 2/20A~ or 200/600A~ depending th the desired
rating
3. Open the clamp and surround 1 single conductor (phase or neutral) if possible in
the centre to improve accuracy, and read the value displayed on screen once it has
stabilised.
1. Connect the black probe to terminal COM and the red probe to terminal
2. Set the function switch to position Ω
3. Connect the test plungers to the circuit and read the value displayed on screen once
it has stabilised.
1. Connect the black probe to terminal COM and the red probe to terminal
2. Set the function switch to position
3. Press SELECT once to display the
4. Connect the test plungers to the circuit and, if the buzzer sounds, the continuity
is good (the current flows).
1. Connect the black probe to terminal COM and the red probe to terminal
2. Set the function switch to position
3. Connect the test plungers to the diode:
(A) Test in the direct direction: connect the black plunger to the cathode and the red
plunger to the anode, measuring the voltage in the direction of a normal diode; the
screen will display 0.5 to 0.7V and the blocked direction will display "OL".
(B) Test in the opposite direction: connect the black plunger to the anode and the
red plunger to the cathode. The diode is good if the display shows "OL".
V~
V
symbol on the screen
V
Ω
V
Ω
V
Ω
V
Ω
V
Ω
V
Ω
11