2. TECHNICAL SPECIFICATION
TYPE
Model
Operating Flow Range
Dewpoint
Air Quality
Maximum Operating Pressure
Minimum Operating Pressure
Maximum Inlet Temperature
Minimum Inlet Temperature
Regeneration
Nominal pressure drop across desiccant bed
Standard Electrical Supply
Others Available on Request
Controls
Noise Level
Media
Material
Construction
3. UNPACKING
Although domnick hunter takes every precaution with unpacking, it is advisable after carefully
removing the dryer from its box and packing material to carry out a thorough visual inspection for
any sign of transit damage incurred after leaving our factory.
Any damage should be reported immediately to the carrier and domnick hunter limited and/or the
Distributor from where it was purchased.
Nominal
Optional
including filtration
Standard
Optional
Column
In/Outlet Head
Finish
HEATLESS
DM
3 scfm - 13 scfm (2L/s - 6 L/s)
-40
o
C (-40
o
F)
-70
o
C (-94
o
F)
ISO 8573.1 Class 1.2.1
Optional Class 1.1.1
10.5 bar g (150 psi g)
4 bar g (58 psi g)
50
o
C (122
o
F)
5
o
C (41
o
F)
Pressure Swing Adsorption (PSA)
140mBar (2 psi g)
240V AC / 1PH / 50Hz
110V AC / 1PH / 60Hz
Cam Timer
Pneumatic Cam Timer
75 db(A)
Desiccant
High tensile extruded aluminium
Pressure die cast high tensile aluminium
Alocrom anti-corrosion protection and dry
powder epoxy painted.
Column snowstorm filled with desiccant
material and contained between the inlet
and outlet head using high tensile bolts.
3