For Juno T, TU, R and V series Trac connectors
These connectors are intended for use with Juno T, TU, R or V
Trac systems only. They are to be used with the series of Trac
corresponding to the connector series, i.e. "T" connectors are
used with "T" series Trac, etc.
The diagrams at left are for illustrative purposes and do not
represent a specific connector.
Polarity Line
Polarity Line
Polarity
All Trac components are both mechanically and visually polarized
to assure proper connections and to simplify installation
Trac face has polarity line which indicates positive side "P".
Trac connectors have embossed arrow which must point to Trac
polarity line when installed.
Trac Electrical Feeds
For electrical feed at outlet box.
1. Make sure the power is OFF!
2. Attach fixture strap to outlet box (for adjustable, "T" and "X"
connectors a T27 cover plate is required).
3. Insert feed connector fully into Trac with arrow pointing toward
Trac polarity line and secure with set screw.
4. Attach Trac to ceiling following instructions supplied with the
Trac section.
5. Secure feed connector to fixture strap with lock nut and
nipple provided.
6. Pull wire out of outlet box through connector opening.
7. Fasten positive wire to screw terminal marked "P" for single
circuit Trac or to screw terminal marked "P
(TU series). For two circuit Trac only, fasten the second positive
wire to screw terminal marked "P
".
2
8. Fasten white wire (neutral) to screw terminal marked "N".
9. Replace feed connector cover and secure with screw.
For electrical feed from above away from outlet box.
1. Make sure the power is OFF!
2. Remove any knockouts, if required, before attaching conduit
or BX. Secure conduit or BX to the Trac connector with
proper fittings.
3. Insert feed connector fully into Trac with arrow pointing toward
Trac polarity line and secure with set screw.
4. Attach Trac to ceiling following instructions supplied with the
Trac section.
5. Fasten positive wire to screw terminal marked "P" for single
circuit Trac or to screw terminal marked "P
(TU series). For two circuit Trac only, fasten the second positive
wire to screw terminal marked "P
".
2
6. Fasten white wire (neutral) to screw terminal marked "N".
7. Replace feed connector cover and secure with screw.
1300 South Wolf Road • Des Plaines, IL 60018 • Phone 800-323-5068 • www.junolightinggroup.com
INSTALLATION INSTRUCTIONS
Juno T, TU, R and V series Trac connectors
Polarity Arrow
Polarity Arrow
" for two circuit Trac
1
" for two circuit Trac
1
Polarity Line
Polarity Line
Polarity Arrow
4-inch Octagonal Outlet Box
Black Wire (Positive)
White Wire (Neutral)
Fixture Strap
Screw Terminals
Feed Connectors
Locknut
Feed End Fitting
with Set Screw
BX or Conduit
Feed Connector
Threaded
Connector
Connector
Cover
©2016 Acuity Brands Lighting, Inc.
Polarity Arrows
Polarity Line
Polarity Arrow
Dead End Fitting
with Set Screw
Cover for Outlet Box
and Connector
Feed End Fitting
with Set Screw
Rev 2/16
P3927 pg 1 of 2