1) Positive Lead
SPECIFICATION
2) Negative Lead
Battery type: 9V
3) LCD Display
DC voltage: 200mV - 1000V
4) Function Selector
AC voltage: 200 - 750V
5) 5A DC Jack
DC current: 200μA - 5A
6) VΩmA Jack
Resistance: 200 ohm - 2000k ohm
7) Common Jack
8) hFE Socket
As part of our ongoing product development, specifications of Silverline
products may alter without notice
ACCURACY
Accuracy is specified for a period of one year after calibration and within
temperature range 18° - 28°C with 80% max relative humidity
Before Use
Unpacking
Ensure that all parts of your multimeter are present and in good condition.
If any part is missing, or damaged, have such parts replaced before
attempting to use this tool
Assembly
1. Remove the two screws from the back of the multimeter.
2. Take the back off and insert a 9V battery.
3. Connect the battery - align the battery with the connector so that the
terminals on the battery and the connector snap-fit together securely.
4. Insert the battery into the compartment, replace the panel carefully
and re-tighten the screws.
Operating
NOTE:
• Every time this multimeter is used, inspect the test leads, connectors
and probes for damage. If the leads are damaged have them replaced
by an authorised service centre
• If in doubt as to range required, select the highest range and then
reduce it as necessary until satisfactory resolution is obtained
• If the figures '1' or '-1' are displayed, this indicates the reading is out of
the set range
Voltage measurement
• Connect the red Positive Lead (1) to the VΩmA Jack (6)
• Connect the black Negative Lead (2) to the COM (Common) Jack (7)
• Rotate the Function Selector (4) to select the required voltage range in
the correct DC or AC range
• Connect the test leads to the circuit being measured
• Turn on the power to the circuit being measured. The value of the
voltage passing through the circuit should be displayed on the LCD
Display (3), along with the polarity (if reversed only)
1) Fil positif
2) Fil négatif
3) Écran à cristaux liquides
4) Sélecteur de fonction
5) Borne 5 A CC
6) Borne VΩmA
7) Borne COM
8) Prise hFE
Dans le cadre du développement de nos produits, les caractéristiques
techniques des produits Silverline peuvent être modifiées sans préavis.
Précision
La précision est indiquée pour une période d'un an à la suite de la calibration
et dans une plage de températures allant de 18 °C à 28 °C, sous 80 %
d'humidité relative.
Avant utilisation
Déballage
Veillez à retirer tout le matériau d'emballage et familiarisez-vous avec toutes
les caractéristiques du produit. Si une pièce est endommagée ou manquante,
faites-la réparer ou remplacer avant d'utiliser l'appareil.
Insertion de la pile
1. Dévissez les deux vis de l'arrière de l'appareil
2. Enlevez le couvercle avec soin
3. Raccordez la pile neuve sur les cosses prévues à cet effet
4. Insérez la pile dans son compartiment, remettez le couvercle en place
et revissez les vis
Mode d'emploi
NOTA:
• A chaque mise en service, vérifiez l'existence d'éventuels dommages sur les
fils de contrôle, connecteurs et sondes. Si les fils sont endommagés, faites-
les remplacer immédiatement par un centre de réparation agréé
• En cas de doute quant à la plage requise, sélectionnez la plage la plus élevée
puis réduisez-la jusqu'à obtenir une résolution satisfaisante
• Si les chiffres '1' ou ''-1' s'affichent, la mesure est en-dehors de la plage
Mesure de tension
• Branchez le fil positif rouge (1) à la borne VΩmA (6)
• Branchez le fil négatif noir (2) à la borne COM (Commune) (7)
• Sélectionnez la plage de tension appropriée dans la plage c.c. ou c.a. à
l'aide du sélecteur de fonction (4)
• Branchez les fils de contrôle sur le circuit à mesurer
• Mettez le circuit sous tension. La valeur de la tension du circuit, ainsi
que la polarité (si en polarité inversée), s'affichent sur l'écran à cristaux
liquides (3)
Mesure d'intensité c.c.
• Pour des mesures inférieures à 200 mA : branchez le fil positif rouge (1)
dans la borne VΩmA (6)
DC Current measurement
• For measurements up to 200mA: Connect the red Positive Lead (1) to
the VΩmA Jack (6)
• For measurements above 200mA, up to max 5A: Connect the red
Positive Lead (1) to the 5A Jack (5). Please note the 5A circuit is unfused
• Connect the black Negative Lead (2) to the COM (Common) Jack (7)
• Rotate the Function Selector (4) to select the required amperage range
• Make the circuit being measured open, connect the test leads across the
opening to create a bridge over the gap
• Turn on the power to the circuit being measured, the value of the current
passing through the circuit should be displayed on the LCD Display (3)
Resistance measurement
NOTE: If the resistance to be measured is part of a circuit, turn off and
disconnect the power and discharge all capacitors before measurement.
• Connect the red Positive Lead (1) to the VΩmA Jack (6)
• Connect the black Negative Lead (2) to the COM (Common) Jack (7)
• Rotate the Function Selector (4) to select the required ohm range
• Connect the test leads to the circuit being measured
• The resistance value should now be displayed on the LCD Display (3)
NOTE: While measuring resistance about 1MΩ and above, the meter may
take a few seconds to stabilise. This is normal for high resistance readings.
Diode testing
• Connect the red Positive Lead (1) to the VΩmA Jack (6)
• Connect the black Negative Lead (2) to the COM (Common) Jack (7)
• Rotate the Function Selector (4) to the
• Connect the red test lead to the anode of the diode to be tested and the
black test lead to the cathode of the diode
• The approx. forward voltage drop of the diode should be displayed on
the LCD Display (3)
NOTE: If the connection is reversed, only figure '1' will be displayed
Continuity testing
• Connect the red Positive Lead (1) to the VΩmA Jack (6)
• Connect the black Negative Lead (2) to the COM (Common) Jack (7)
• Rotate the Function Selector (4) to the
• Connect the test leads to the circuit being measured
• If continuity exists (i.e. resistance is less than approx. 50Ω), the built-in
buzzer will sound
Transistor testing
• Rotate the Function Selector (4) to the 'hFE' position
• Determine whether transistor is NPN or PNP
• Locate the emitter, base and collector leads
• Insert the leads into the appropriate holes in the 'hFE' Socket (8): The left
side of the socket is configured for PNP, the right side for NPN
• The approximate hFE value will be displayed on the LCD display at the
testing condition of base current 10μA and Vce 3V
CARACTERISTIQUES
• Pour des mesures supérieures à 200 mA et jusqu'à 5 A maximum :
TECHNIQUES
branchez le fil rouge dans la borne 5 A (5). Veuillez noter que le circuit 5 A ne
Pile: 9 V
contient pas de fusible
Tension c.c: 200mV - 1000 V
• Branchez le fil négatif noir (2) à la borne COM (Commune) (7)
Tension c.a: 200 - 750 V
• Sélectionnez la plage d'intensité à l'aide du sélecteur de fonction (4).
Intensité c.c:200μA - 5 A
Résistance: 200 ohm -
• Ouvrez le circuit pour pouvoir brancher les fils de contrôle et placez le
2000k ohm
multimètre à l'endroit de l'ouverture
• Mettez le circuit sous tension. La valeur de l'intensité du circuit, ainsi que la
polarité (si en polarité inversée), s'affichent sur l'écran à cristaux liquides (3)
Mesure d'une résistance
NOTA : Pour mesurer une résistance faisant partie d'un circuit, débranchez et
coupez l'alimentation et déchargez tous les condensateurs avant de procéder
à la mesure.
• Branchez le fil positif rouge (1) à la borne VΩmA (6)
• Branchez le fil négatif noir (2) à la borne COM (Commune) (7)
• Sélectionnez la plage de résistances (Ω) requise à l'aide du sélecteur
de fonction (4)
• Branchez les fils de contrôle sur le circuit à mesurer
• La valeur de résistance s'affiche sur l'écran à cristaux liquides (3)
NOTA : A la mesure de résistances d'environ 1 MΩ et plus, il est possible
que l'appareil mette quelques secondes à se stabiliser. Cela est normal
pour les mesures de résistances élevées
Test d'une diode
• Branchez le fil positif rouge (1) à la borne VΩmA (6)
• Branchez le fil négatif noir (2) à la borne COM (Commune) (7)
• Sélectionnez la fonction
• Raccordez le fil de contrôle rouge à l'anode de la diode à tester et le fil de
contrôle noir à la cathode de la diode
• La chute de tension directe approximative de la diode s'affichera sur l'écran
à cristaux liquides (3)
NOTA : Si le branchement est inversé, l'écran affichera uniquement un "1".
Test de continuité
• Branchez le fil positif rouge (1) à la borne VΩmA (6)
• Branchez le fil négatif noir (2) à la borne COM (Commune) (7)
• Tournez le sélecteur de fonction (4) sur
• Branchez les fils de contrôle sur le circuit à mesurer
• La présence de continuité (signifiant une résistance inférieure à env. 50
Ω) est signalée par un signal sonore
Test de transistor
• Tournez le sélecteur de fonction (4) sur la position « hFE »
• Déterminez si le transistor est du type NPN ou PNP
• Identifiez les fils de l'émetteur, de la base et du collecteur
• Insérez les fils dans les trous appropriés de la prise hFE (8) : le côté
gauche de la prise est configuré pour un transistor PNP et le côté droit
pour NPN
• La valeur hFE approximative s'affichera sur l'écran à cristaux liquides à
la condition d'essai d'une intensité de base de 10 µA et Vce de 3 V
setting
setting
à l'aide du sélecteur de fonction (4)
Test signal use
• Rotate the Function Selector (4) to the
• A test signal (50Hz) appears between VΩmA and COM jack, the output
voltage is approx to 5V p-p with 50KΩ impedence
Storage and Maintenance
WARNING: Ensure that the test leads are disconnected prior to storing or
carrying out any maintenance on this tool
• Store the unit in a clean, dry environment within the temperature range
-10°C to +50°C
• If the test leads are damaged in any way, replace them with new leads
of the same type and specification
• If the unit malfunctions, have it serviced by a suitably qualified
technician
• If you need to replace the battery, use method described in 'Assembly'
EC Declaration of Conformity
The undersigned: Mr Darrell Morris
as authorised by: Silverline Tools
Declares that the
Name/ model: Digital Multimeter
Type/ serial no: 589681
Conforms to the following Directives:
• Low Voltage Directive 2006/95/EC
• EMC Directive 2004/108/EC
• EN61010-1:2001
• EN61010-031:2002+A1:2008
• EN61326-1:2006
• EN61326-2-2:2006
The technical documentation is kept by: Silverline Tools
Notified body: Shenzhen Easy Test Electronic Products Co Ltd
Place of declaration: Futian, Shenzhen, China
Date: 01/11/11
Signed by:
Director
Name and address of Manufacturer or Authorised representative:
Silverline Tools, Boundary Way, Lufton Trading Estate, Yeovil, Somerset,
BA22 8HZ United Kingdom
Utilisation du signal d'essai
• Tournez le sélecteur de fonction (4) sur la position
• Un signal d'essai (50 Hz) est généré entre les bornes VΩmA et COM, dont
la tension de sortie est d'environ 5 V crête à crête, pour une impédance de
50 kΩ
Rangement et entretien
AVERTISSEMENT: Assurez-vous que les fils de contrôle soient débranchés
avant de ranger l'appareil ou d'effectuer une opération d'entretien.
• Rangez l'appareil dans un endroit sec et propre dans une plage de
température de -10 à +50 ºC
• Si les fils de contrôle présentent une quelconque anomalie, remplacez-
les avec des fils du même type et de caractéristiques techniques
identiques
• En cas de dysfonctionnement, faites réparer l'appareil par un technicien
qualifié
• Pour remplacer la pile, suivez les consignes indiquées dans la section «
Insertion de la pile »
Déclaration de conformité CE
Le soussigné : Mr Darrell Morris
Autorisé par : Silverline Tools
Déclare que le produit :
Nom/modèle : Multimètre numérique
Nº de série/Type : 589681
Est conforme aux directives suivantes :
• Directive sur les basses tensions 2006/95/CE
• EMC Directive 2004/108/CE
• EN61010-1:2001
• EN61010-031:2002+A1:2008
• EN61326-1:2006
• EN61326-2-2:2006
La documentation technique est conservée par : Silverline Tools
Organisme notifié : Shenzhen Easy Test Electronic Products Co Ltd
Lieu de la déclaration : Futian, Shenzhen, Chine
Date : 01/11/11
Signature :
Directeur
Nom et adresse du fabricant ou de son représentant agréé :
Silverline Tools, Boundary Way, Lufton Trading Estate, Yeovil, Somerset,
BA22 8HZ Royaume-Uni
www.silverlinetools.com
setting