REMOTE TEST DEVICE FOR ROUND EMERGENCY LED DRIVER (BBU)
NOTE: Compatible with ETi products 70112201 and 70114401
NOTE: Keep your receipt and these instructions for proof of purchase.
If you are unfamiliar with electrical installations/testing, we recommend you contact a
qualified electrician to do the installation.
TESTING BBU OPERATION
Signal range of 98 ft.
One remote test switch will control all round emergency packs within 98ft.
After wiring is complete, apply A.C. power. Check if the indicator light is illuminated or not, which will indicate the battery's charging situation.
The battery in this unit may not be fully charged. A short-term discharge test may be conducted after the BBU has been charging for 1 hour. Charge for 24 hours before conducting a long-
term discharge test.
Sold Separately
Signal Receiver
OPERATION (INDICATOR STATUS)
Test Mode
Test Switch Operation
Short Term Test
Pressed once
Long Term Test
Pressed twice (2s) in sequence
Operation Mode
Test Switch Operation
AC Mode (1)
Not Pressed
Emergency Mode (1)
Not Pressed
Emergency Mode (2)
Pressed once
When indicator flashes (0.2s) ON and (0.2s) OFF fast or goes off, the emergency backup pack is abnormal.
Problem
Contact the manufacturer.
WARNING
NOTE: Please press test switch or wireless remote button A (in once) and make certain the battery is turned off, before installation, maintenance,
storage or shipping.
Risk of Electric Shock
SELF-DIAGNOSTIC (MAINTENANCE)
The integrated Self- Diagnostic circuitry will automatically conduct 1 monthly 30-second and annual 90-minute tests to verify proper emergency capability per Life Safety Code
requirements. NFPA 101, Life Safety Code Outlines the following schedule:
• Monthly - During AC mode, the system conducts a (30)seconds self-discharge test of the emergency led driver every 30 days. And automatically restore to normal charging after (30)
seconds dis-charged.
• *Annually - During AC mode, the system conducts a (90)minutes self-discharge test of the emergency led driver every 365 days. And automatically restore to normal charging after
fully dis-charged.
• "Written Records of the Testing should be kept by the owner for inspection by the authority having jurisdiction." If the charging indicator is
flashing rapidly or off, contact manufacturer.
WARNING: Carefully read and understand the information given in this manual before beginning the assembly and installation. Failure to do so could lead to electric shock, fire, or
other injuries which could be hazardous or even fatal. • The emergency driver is only used for emergency back up of LED light load, do not use for other than intended use.
NOTICE: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired operation. These limits are designed to provide reasonable protection against harmful interference
in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio
or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna, increase the separation between the equipment and the receiver, connect the equipment into an outlet on a circuit different from that to which
the receiver is connected, and consult the dealer or an experienced radio/TV.
• Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
See website for Warranty, Troubleshooting or Care and Cleaning details at www.ETiSSL.com.
USE AND CARE GUIDE
Charge Indicator & Test Switch
Wireless Remote
Operation
Pressed Button A once
Pressed Button B once
Wireless Remote
Operation
Not Pressed
Not Pressed
Pressed Button A once
Questions, problems, missing parts? Call ETiSSL Customer Service 8 a.m. - 5 p.m., CST, Monday - Friday
1-855-ETI-SSLI (1-855-384-7754) www.ETiSSL.com
PACKAGE CONTENTS
Part
Description
A
Remote
Indicator Status
Comment & Solutions
2s ON and 2s OFF (slow
Battery is conducting a 30s short-term emergency
flashing)
test
2s ON and 2s OFF (slow
Battery is conducting a long-term emergency test
flashing)
until battery is fully discharged
Indicator Status
Comment & Solutions
ON (Not flashing)
Battery is charging
2s ON and 2s OFF (slow
Every 365 days conducts a 90 minute test of the
flashing)
emergency led driver*
OFF
Battery is turned off
Model # 70203101
Part # RTS-3902
Quantity
1
A

Publicidad

loading

Resumen de contenidos para ETI 70203101

  • Página 1 Part # RTS-3902 USE AND CARE GUIDE REMOTE TEST DEVICE FOR ROUND EMERGENCY LED DRIVER (BBU) PACKAGE CONTENTS NOTE: Compatible with ETi products 70112201 and 70114401 NOTE: Keep your receipt and these instructions for proof of purchase. Part Description Quantity...
  • Página 2 GUIDE D’UTILISATION ET D’ENTRETIEN TÉLÉCOMMANDE D’ESSAI POUR LE TRANSFO DEL D’URGENCE (BBL) ROND CONTENU DE L’EMBALLAGE REMARQUE : Compatible avec les produits ETi 70112201 et 70114401. REMARQUE : Gardez votre facture ainsi que ces instructions comme preuves d’achat. Pièce Désignation Quantité...
  • Página 3 Las informaciones sobre la garantía, la solución de problemas, el mantenimiento y la limpieza se puede encontrar en el sitio web: www.ETiSSL.com. ¿Preguntas, problemas, piezas faltantes? Llame al Centro de Atención al Cliente de ETi en el horario de 8 a.m. - 5 p.m., HEC, de lunes a viernes.