Before installation read the instructions
ELECTRIC BOX FOR LEVEL WATER CONTROL - WELL OR RESERVOIR
- Water level control by level electrodes
- Main switch
- Set maximum current (A): by thermic relay
- In single phase motors must be installed a capacitor, according motor power
- Could be connected with float switch, pressure switch, alarm, etc.
- Protections
- Dry running
- Overload
- High voltage
- Circuit break
- Lack phase (three phase motors)
- For single phase or three phase electropumps
INDICATIONS
MOTOR
ON
ORION
CONTROL de NIVEL
(green) - Electropump on
S120
With water (green) - Electropump ready to start
C/ ACUA
Lack water (red) - Electropump off
S/ ACUA
Tension (yellow)
230/400 VAC
1~ PHASE MOTORS
N F C C C N F P
P
Com
Min Max
IN
CAP.
OUT
PRESS
WELL
1 ~
M
N - F = power supply 1~220/230 V
C - C = capacitor
C
= motor (capacitor - start)
N
= motor (com)
F
= motor (L - main)
P - P = connection (pressure switch, etc)
Com = Com
Min = minimum water level (pump off)
OVERLOAD
(red) - Electropump off
Connections
3~ PHASE MOTORS
N R S T U V W P
P
IN - POWER SUPPLY OUT - MOTOR
PRESS
3 ~
M
N-R-S-T = power supply 3~400 V +n
U-V-W = motor
P - P = connection (pressure switch, etc)
Max = maximum water level (pump on)
Com
Min Max
WELL
1~PHASE CONTROL BOX
13
13
1
1
3
3
5
5
A1
A1
A2
A2
2
2
14
14
4
4
6
6
1
1
3
3
5
5
96
96
98
98
97
97
95
95
2
2
4
4
6
6
N
F
C
C
C
N
F
P
P
COM
MIN
MAX
ENTRADA
CONDEN.
SALIDA
PRESS.
POZO
1~ 50 Hz 230 V
1 ~
M
3N~ PHASE CONTROL BOX
13
1
3
5
A1
A2
2
4
6
14
1
3
5
96
98
97
95
2
4
6
N
R
S
T
U
V
W
P
P
COM
MIN
MAX
ENTRADA
SALIDA
PRESS.
POZO
3N~ 50 Hz 400 V
3 ~
M
6
7
5
8
4
9
ORION
3
10
2
11
1
6
7
5
8
4
9
ORION
3
10
2
11
1

Publicidad

loading

Productos relacionados para Saci CSP-M

Este manual también es adecuado para:

Csp-t3