Step 1
Temperature Offset:
Offset the temperature display to read +/- 9° F or +/- 4.5° C.
• Slide the Mode Switch to the Off position
(Step 1). While holding the Reset Button (on the back of the thermostat
body), press the Down Arrow Button until the Offset Indicator appears
(Step 2). Release the Reset Button. (Do not hold the Reset Button
for more than five seconds.) Use the Arrow Buttons to pick the offset
temperature amount. The thermostat will accept the chosen offset after
10 seconds of no activity, or by sliding the Mode Switch to Heat or Cool.
Off
Off
Step 1
Minimum Off Time: To help protect the compressor, the system
will wait five minutes after turning off before turning on again. The
appropriate Mode Indicator Icon (Heat/Cool) will flash on the display
whenever minimum off time is being enforced.
Icon (snowflake or
flame) flashes while
MODE
minimum off time is
being enforced
ADDITIONAL THERMOSTAT SETTINGS
Settings in this section are not necessary for all systems. These settings,
however, may optimize energy use and comfort levels, especially if a heat
pump system is being used.
System Type Adjustment: Your Clear Comfort™ thermostat is set at
the factory to operate a standard fossil fuel furnace heating system. This
setting can be changed to better accommodate other heat sources, fan
types or a heat pump system.
• Slide the Mode Switch to the OFF position (Step 1). While holding the
Reset Button (on the back of the thermostat body), press the Down Arrow
Button until the Offset Indicator appears (Step 2). Release the Reset
Button. (Do not hold the Reset Button for more than five seconds.) Press
the Reset Button again (Step 3). (The Offset setting will not be lost.) If
using a heat pump, toggle to "HP" using the Up or Down Arrow Buttons.
To return to the furnace setting ("F"), press the Up or Down Arrow Button
(Step 4). The thermostat will accept the setting after 10 seconds of no
activity, or by sliding the Mode Switch to Heat or Cool.
Off
RESET
Off
Down Arrow
Step 1
Step 2
Up Arrow
RESET
Step 2
THERMOSTAT FIG MINIMUM OFF TIME MU
RESET
Down Arrow
Step 2
THERMOSTAT FIG MINIMUM OFF TIME MU
601-VO
R RC W Y O/B G C
˚
set
f
cool
auto fan
FAN
RESET
SW1
Off
Arrow up
RESET
Arrow down
Step 3
THERMOSTAT FIG MINIMUM OFF TIME MU
Installation for Heat Pump Systems:
If installing your Clear Comfort™ thermostat on a heat pump system,
the following instructions are necessary.
Arrow up
• Insert the additional jumper (included) into the Y and W terminals.
• If a B wire is part of your installation, connect it to the O/B terminal.
Arrow down
601-VO
Move the jumper located near the right edge on the back of the
thermostat body from the Cool (O) position on the pins to the Heat (B)
position on the pins. If an O wire is part of your installation, connect it to
the O/B terminal. Leave the jumper on the Cool (O) position.
RESET
SW1
Typical wiring for a heat pump system
Arrow up
Arrow down
Fan Jumper: Correct placement of this jumper optimizes energy use and
comfort levels for the connected system type.
• For electric and heat pump systems, move the jumper located in the top-
right corner on the back of the thermostat body from the Gas/Oil Heat
position on the pins to the Electric Heat position.
• For gas or oil systems, verify that the jumper is in the Gas/Oil
Heat position.
601-VO
Electric
Furnace
R RC W Y O/B G C
AAA
Minimum Cycle Period Adjustment:
The cycle period is the minimum time in minutes between each heating or
cooling cycle. As a default, your thermostat's minimum cycle period is set
RESET
to optimize energy use and comfort levels. The default can be changed
based on desired cycle times for specified heat systems.
SW1
Recommended Cycle Periods
F
HP
Arrow up
or
Arrow down
Step 4
THERMOSTAT FIG MINIMUM OFF TIME MU
R RC W Y O/B G C
G
Y W
R
0/B
RC
G
Y
R
0/B
Gas/Oil
Furnace
Electric furnace
Heat
Cool
(B)
(0)
Heat Pump
System Type
1-Stage gas furnace heat
with electric fan
1-Stage gas furnace heat
with gas fan
1-Stage oil furnace
Steam and gravity
Hot water system
High efficiency furnace
Electric furnace
1-Stage heat pump
Compressor
Electric
Gas/Oil
Furnace
Furnace
AAA
Heat
Cool
(B)
(0)
Heat Pump
Jumper position if B wire is connected
Electric
Gas/Oil
Furnace
Furnace
Gas/Oil furnace
AAA
Heat
Cool
(B)
(0)
Heat Pump
Cycle Period
(Minutes)
12
12
12
60
20
20
6
20
20