Fagor TTT 8000 Manual De Instrucciones página 15

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

2. RF OUTPUT: RF output
2.1. Out Frequency:
50,5 ÷858 MHz.
2.2. Out Level:
65 ÷80 dBuV.
2.3. Out RF:
Enables/disables the RF output.
3. DVB-T OUTPUT: DVB-T output
3.1. DVB T Mode:
2K, 8K.
3.2. QAM Mode:
QPSK, 16 QAM, 64 QAM.
3.3. Code Rate:
FEC 1/2, 2/3, 3/4, 5/6, 7/8.
3.4. Guard Interval:
1/4, 1/8, 1/16, 1/32.
3.5. Bandwidth:
6, 7, 8 MHz.
3.6. IQ mode:
normal, Inverted.
4. OUTPUT SERVICES
- This function is only available when the tuner is tuned.
4.1. List of Services:
list of services.
Press
to view the list.
Press
to select the service.
Press
to enter the service parameters.
– A "+" sign followed by the name of the service indicates
that this service is in the output multiplex.
– A " * " sign before the name indicates an encrypted
service.
4.1.1. Active:
enables the service on output MUX
(use
to select and press
4.1.2. LCN:
Allows assigning a LCN (Logical Channel
Number) between 1 and 999 to the services at the
output (select with
stands for NO LCN).
- To change the LCN is necessary having the NIT Mode in
"Local" option. See 5.1.
4.1.3. Program Number:
indicates the service PN.
4.2. Output MUX BW:
indicates the total % of the output
MUX occupied.
- It is not recommendable to work with the output MUX BW
above 80%, as the services may increase their bitrate during
transmission. (Output MUX BW >100%: Status LED in yellow).
4.3. Active All:
actives in the output all the input services.
"Press
".
OK
- With encrypted services there is the risk of overload the
processing capacity of the CAM.
4.4. Read Services:
reads the transponder services.
"Press
".
OK
5. PSI EDIT:
Allows the Output's NIT configuration.
5.1. NIT Mode:
Pass-Through / LOCAL selection. If local is
chosen, allows modifying the following parameters.
).
OK
and press
; 000
OK
5.2. Network Name:
Allows living a name to the network.
5.3. Network ID:
(give the same value as the Orig.Net.ID).
5.4. TS ID:
Some receivers need a different TS ID for every
memorised module (value between 0 and 65535).
5-5 Orig. Net. ID:
Original Network Identifier by Country
(see table 3).
5.6. Vr. NIT:
NIT version table (TTT-CI 8000).
5.7. Vr. SDT:
SDT version table (TTT-CI 8000).
6. CAM: access to MMI and CAM menus
(TTT-CI 8000)
6.1. Read MMI:
Open the session with the MMI
(only option available if session is not open).
If the session is open, the last option is read again.
6.2. Close MMI:
Closes the session with the MMI.
It's recommended to close the MMI session once
finished the access.
6.3. MMI menu:
Options list or CAM information.
It can appear a first information line followed by the list
of options with a number. The last option (0.Quit) goes
to the precedent menu. If the information to show
is longer than the display size, push
of the text.
6.4. MMI Enquiry:
CAM's data introduction (example
insert PIN). Look at point 6.5.
6.5. Enter User Input:
CAM's data introduction.
7. MEMORY
- Automatic save: 30 minutes after the last button
is pressed, the current data will be stored in the
TTT 8000.
7.1. Save Configuration:
7.2. Restore Configuration:
stored in the unit to be recovered.
7.3. Save Configuration, Device to UCF 300:
enables the configuration stored to be saved with an
identifying name in one of the 26 memories of the
UCF 300.
7.4. Load Configuration, UCF 300 to Device:
recovers the data in one of the UCF 300's memories
with data recorded from an TTT for cloning on another
TTT 8000.
15
to read the rest
Stores current programming.
Enables the configuration

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ttt-ci 8000

Tabla de contenido