TwinController Mk2
The TwinController is software controlled with MOTION FLOW and not mechanical like other controllers.
Therefore, it reacts completely differently compared to the to the usual controllers.
The TwinController makes an evaluation for the gradual increase or decrease of your fans.
In the course of a cycle it will automatically find the appropriate capacity level of the fans to maintain
the programmed temperature.
This new technique means no more temperature fluctuations and fan noise is kept to a minimum.
Fans of different capacities
When using ventilators of different capacity e.g. 1000m3 IN and 2000m3 OUT, the Twincontroller
will create an optimal pressure inside your room.
Please make sure the smaller ventilator is plugged into the inlet socket (FAN AIR IN)
The bigger fan plugs into the exhaust socket (FAN AIR OUT).
Usage
1. Connect the ventilators to the sockets on the front of the TwinController
2. Set the MINIMUM ventilation speed (e.g. 30%) using dial knob1
3. Set the temperature (e.g. 25°C) using dial knob2
4. Set the MAXIMUM ventilation speed (e.g. 95%) using dial knob3
5. Place the Temperature Sensor in the middle of the room making sure it is not placed directly
in the air flow.
6. Plug the Switchbox into the mains socket and turn on*
Of course you also can use only 1 ventilator if desired using 'FAN AIR OUT' socket only.
The TwinController will automatically find the right speed for the ventilators to maintain the desired
temperature.
*When the TwinController is first turned on, it will scan the room for 5 minutes to find the correct speed
for the fans. During this time, the ventilators will start running faster and slower as the TwinController
calibrates. After this scanning process the TwinController
will always know the correct running speed for your ventilators and will adjust them accordingly.
Attention: Set a suitable minimum speed for your ventilators! (If set too low, the ventilators may
make some noise, risk of damaging them and the air will not be refreshed adequately.)